NONPOROUS POLYBUTADIENE-COATED SILICAS AS STATIONARY PHASES IN REVERSED-PHASE CHROMATOGRAPHY

被引:59
作者
HANSON, M [1 ]
UNGER, KK [1 ]
SCHOMBURG, G [1 ]
机构
[1] MAX PLANCK INST COAL RES,W-4330 MULHEIM,GERMANY
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 517卷
关键词
D O I
10.1016/S0021-9673(01)95727-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-porous silica of mean particle diameter 1.7 μm (Monospher) was coated with polybutadiene (PBD) following a published procedure. The silicas were prepared with graduated polymer loads up to 8% (w/w). Examination of the PBD-coated packings by means of electron spectroscopy for chemical analysis, scanning electron microscopy, diffuse reflection infrared fourier transform spectroscopy and differential thermal gravimetry indicated that the optimum polymer load was between 1 and 3% (w/w) with regard to a dense coverage corresponding to an average layer thickness of about 4 nm. No silanophilic interactions could be monitored using 1-3% (w/w) coated silicas under reversed-phase conditions. The small particle diameter combined with the chemically stable polymer coating allowed extremely fast and efficient separations of peptides and polypeptides under gradient elution conditions in less than 1 min. © 1990.
引用
收藏
页码:269 / 284
页数:16
相关论文
共 25 条
  • [1] DAVANKOV VA, IN PRESS J CHROMATOG
  • [2] PACKING TECHNOLOGY, COLUMN BED STRUCTURE AND CHROMATOGRAPHIC PERFORMANCE OF 1-2-MU-M NON-POROUS SILICAS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GIESCHE, H
    UNGER, KK
    ESSER, U
    ERAY, B
    TRUDINGER, U
    KINKEL, JN
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01): : 39 - 57
  • [3] HERZOG W, 1984, FARBE LACK, V90, P102
  • [4] EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .4. MOBILE PHASE AND SURFACE-MEDIATED EFFECTS ON RECOVERY OF NATIVE PROTEINS IN GRADIENT ELUTION ON NONPOROUS, MONODISPERSE 1.5-MU-M REVERSED-PHASE SILICAS
    JANZEN, R
    UNGER, KK
    GIESCHE, H
    KINKEL, JN
    HEARN, MTW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 397 : 81 - 89
  • [5] EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .6. DESIGN, CHROMATOGRAPHIC PERFORMANCE AND APPLICATION OF NON-POROUS SILICA-BASED ANION-EXCHANGERS
    JILGE, G
    UNGER, KK
    ESSER, U
    SCHAFER, HJ
    RATHGEBER, G
    MULLER, W
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 476 : 37 - 48
  • [6] KURGANOV A, IN PRESS J CHROMATOG
  • [7] RETENTION BEHAVIOR OF PARACELSIN PEPTIDES ON REVERSED-PHASE SILICAS WITH VARYING N-ALKYL CHAIN-LENGTH AND LIGAND DENSITY
    LORK, KD
    UNGER, KK
    BRUCKNER, H
    HEARN, MTW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 476 : 135 - 145
  • [8] Mackenzie RC, 1982, DIFFERENTIAL THERMAL
  • [9] Mant C. T., 1986, LC LIQ CHROMATOGR HP, V4, P250
  • [10] MONITORING FREE SILANOLS ON REVERSED-PHASE SUPPORTS WITH PEPTIDE STANDARDS
    MANT, CT
    HODGES, RS
    [J]. CHROMATOGRAPHIA, 1987, 24 : 805 - 814