A PROBE FOR SPECIMEN MAGNETIC-RESONANCE MICROSCOPY

被引:21
作者
BANSON, ML
COFER, GP
BLACK, R
JOHNSON, GA
机构
[1] DUKE UNIV,MED CTR,CTR INVIVO MICROSCOPY,DURHAM,NC 27710
[2] GE,CTR CORP RES & DEV,SCHENECTADY,NY 12345
关键词
FORMALIN-FIXED TISSUE SPECIMENS; HELMHOLTZ COIL; MAGNETIC RESONANCE MICROSCOPY;
D O I
10.1097/00004424-199202000-00013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the primary limits to spatial resolution in magnetic resonance (MR) microscopy is the limited signal. The purpose of this study is to build a radiofrequency (rf) probe for MR microscopy or fixed specimens at 300 MHz. The design criteria for the probe were (1) high sensitivity; (2) good rf homogeneity; (3) minimization of B(O) variations. All probes were Helmholtz pairs operating at 300 MHz. Coils were constructed from copper/Teflon/copper microwave substrate which eliminated susceptibility problems from solder and discrete capacitors. Signal-to-noise ratio (SNR) was compared with a conventional solenoid. Phantoms of agar gels and saline-filled tubes were used to characterize the SNR and homogeneity. SNR measurements of the coil pairs showed a marked improvement (up to 60%) over that of the reference solenoid. The region of homogeneity was defined as a 10% variation in signal intensity. This correlated with the coil's inner diameter. Graphs of SNR versus diameter, separation, and copper foil width allowed for optimization of the structure. Using this coil, MR microscopy is now possible on small, fixed specimens with pixels as small as 20 x 20 x 30-mu-m. Work is currently under way exploiting the SNR and homogeneity provided by this probe to determine the degree to which MR microscopy might add to the pathologists' diagnostic tools.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 21 条
  • [1] BRAIN MR - PATHOLOGIC CORRELATION WITH GROSS AND HISTOPATHOLOGY .1. LACUNAR INFARCTION AND VIRCHOW-ROBIN SPACES
    BRAFFMAN, BH
    ZIMMERMAN, RA
    TROJANOWSKI, JQ
    GONATAS, NK
    HICKEY, WF
    SCHLAEPFER, WW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (03) : 551 - 558
  • [2] DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY
    CALLAGHAN, PT
    ECCLES, CD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01): : 1 - 8
  • [3] SENSITIVITY AND RESOLUTION IN NMR IMAGING
    CALLAGHAN, PT
    ECCLES, CD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1987, 71 (03): : 426 - 445
  • [4] CALLAGHAN PT, IN PRESS J MAGN RESO
  • [5] CARVLIN MJ, 1989, AM J NEURORADIOL, V10, P13
  • [6] NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS
    CHO, ZH
    AHN, CB
    JUH, SC
    LEE, HK
    JACOBS, RE
    LEE, S
    YI, JH
    JO, JM
    [J]. MEDICAL PHYSICS, 1988, 15 (06) : 815 - 824
  • [7] HIGH-RESOLUTION IMAGING - THE NMR MICROSCOPE
    ECCLES, CD
    CALLAGHAN, PT
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 68 (02) : 393 - 398
  • [8] MAGNETIC-RESONANCE MICROSCOPY OF CHICK-EMBRYOS IN OVO
    EFFMANN, EL
    JOHNSON, GA
    SMITH, BR
    TALBOTT, GA
    COFER, G
    [J]. TERATOLOGY, 1988, 38 (01) : 59 - 65
  • [9] COUNTER ROTATING CURRENT LOCAL COILS FOR HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING
    FRONCISZ, W
    JESMANOWICZ, A
    KNEELAND, JB
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) : 590 - 603
  • [10] HIRSCH WL, 1989, AM J NEURORADIOL, V10, P923