CROWN-RUMP LENGTH MEASUREMENTS REVISITED

被引:13
作者
KOORNSTRA, G
WATTEL, E
EXALTO, N
机构
[1] SPAARNE ZIEKENHUIS HAARLEM,DEPT OBSTET & GYNAECOL,VAN HEYTHUIJZENWEG 1,2012 CE HAARLEM,NETHERLANDS
[2] FREE UNIV AMSTERDAM,DEPT MATH & COMP SCI,1007 MC AMSTERDAM,NETHERLANDS
来源
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY | 1990年 / 35卷 / 2-3期
关键词
Crown-rump length; Ultrasound;
D O I
10.1016/0028-2243(90)90153-R
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Clinical and ultrasound data of 403 first-trimester pregnancies were collected prospectively. For our CRL study, two groups of patients were selected: Group A with an optimal (menstrual) history (111 patients, 156 CRL measurements) and Group B with available BBT charts (17 patients, 27 CRL measurements). Compared to the Robinson CRL curve (SD ± 4.7 days) the curve of group A (SD ± 4.4 days) showed a small underestimation of gestational age of 2.5 days in the 8th week, gradually declining (p < 0.001). The CRL curve of group B (SD 4.3 days) is parallel to the group A curve, displaced 2.9 days to the left, and did not differ significantly from the Robinson curve. In conclusion: in contrast to suggestions in literature there is no need to revise the original CRL curve of Robinson. For individual variations in CRL measurements not only measure errors but also variations in the time of implantation and/or start of growth are responsible. © 1990.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 14 条
  • [1] A CLINICAL LOOK AT EARLY POSTIMPLANTATION PREGNANCY FAILURE
    BRAMBATI, B
    LANZANI, A
    [J]. HUMAN REPRODUCTION, 1987, 2 (05) : 401 - 405
  • [2] ULTRASONIC MEASUREMENT OF FETAL CROWN-RUMP LENGTH AS A METHOD OF ASSESSING GESTATIONAL AGE
    DRUMM, JE
    CLINCH, J
    MACKENZIE, G
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1976, 83 (06): : 417 - 421
  • [3] ASSESSMENT OF PRENATAL AGE FROM CROWN-RUMP LENGTH DETERMINED ULTRASONICALLY
    DRUMM, JE
    ORAHILLY, R
    [J]. AMERICAN JOURNAL OF ANATOMY, 1977, 148 (04): : 555 - 560
  • [4] MACGREGOR SN, 1987, OBSTET GYNECOL, V70, P344
  • [5] FETAL GROWTH DELAY IN THREATENED-ABORTION - AN ULTRASOUND STUDY
    MANTONI, M
    PEDERSEN, JF
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (07): : 525 - 527
  • [6] ENDOCRINE PROFILES IN EARLY PREGNANCIES WITH DELAYED IMPLANTATION
    NAAKTGEBOREN, N
    DEVROEY, P
    WISANTO, A
    TRAEY, E
    VANSTEIRTEGHEM, AC
    [J]. HUMAN REPRODUCTION, 1986, 1 (01) : 9 - 14
  • [7] EARLY FETAL GROWTH DELAY DETECTED BY ULTRASOUND MARKS INCREASED RISK OF CONGENITAL-MALFORMATION IN DIABETIC PREGNANCY
    PEDERSEN, JF
    MOLSTEDPEDERSEN, L
    [J]. BRITISH MEDICAL JOURNAL, 1981, 283 (6286) : 269 - 271
  • [8] FETAL CROWN-RUMP LENGTH MEASUREMENT BY ULTRASOUND IN NORMAL-PREGNANCY
    PEDERSEN, JF
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (11): : 926 - 930
  • [9] CRITICAL EVALUATION OF SONAR CROWN-RUMP LENGTH MEASUREMENTS
    ROBINSON, HP
    FLEMING, JEE
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1975, 82 (09): : 702 - 710
  • [10] SONAR MEASUREMENT OF FETAL CROWN-RUMP LENGTH AS MEANS OF ASSESSING MATURITY IN FIRST TRIMESTER OF PREGNANCY
    ROBINSON, HP
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1973, 4 (5883): : 28 - 31