MEASURING POTENTIAL DOUBLING TIMES OF MURINE TUMORS USING FLOW-CYTOMETRY

被引:43
作者
CARLTON, JC
TERRY, NHA
WHITE, RA
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT EXPTL RADIOTHERAPY,HOUSTON,TX 77030
[2] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT BIOMATH,HOUSTON,TX 77030
来源
CYTOMETRY | 1991年 / 12卷 / 07期
关键词
CELL KINETICS; BROMODEOXYURIDINE; MATHEMATICAL MODELS; NU-FUNCTION; MURINE TUMORS;
D O I
10.1002/cyto.990120709
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometric analysis of bromodeoxyuridine (BrdUrd) labeled cells has led to the description of various methods for determining population potential doubling times (T(pot)) from samples obtained at a single time point. There have been several reports of results from human tumor samples using these various methods of analysis, but little documentation of the validity of these approaches in experimental tumor models. Recently, we reported results using in vitro cell cultures and determined the most reliable method for these. In this paper we report the results of this methodology when applied to two in vivo murine tumor models (MCaK and FSA). The analytic approach tested is summarized as follows: The relative movement (RM(lu)(t)), a measure of the mean DNA fluorescence of BrdUrd-labeled cells that have not undergone division at the time of sampling, and a quantity-nu, a function of the fractions of BrdUrd-labeled divided and undivided cells, were measured for a series of time points following labeling. From each value of RM(lu)(t) an estimate of the length of S-phase (T(s)) was computed and from each nu and T(s) a value for T(pot) was found. These results were compared to the values of T(s) and T(pot) obtained by fitting all the values simultaneously. Tumor MCaK values of T(s) and T(pot) of 9.6 and 28.0 h were obtained from fitting all of the data. Tumor FSA gave values of 16.8 and 42.3 h for T(s) and T(pot), respectively. The results of this analysis show that single time point measurements can give reliable estimates of T(s) and T(pot).
引用
收藏
页码:645 / 650
页数:6
相关论文
共 15 条
  • [1] A METHOD TO MEASURE THE DURATION OF DNA-SYNTHESIS AND THE POTENTIAL DOUBLING TIME FROM A SINGLE SAMPLE
    BEGG, AC
    MCNALLY, NJ
    SHRIEVE, DC
    KARCHER, H
    [J]. CYTOMETRY, 1985, 6 (06): : 620 - 626
  • [2] BEGG AC, 1989, BR I RADIOL REP, V19, P113
  • [3] CHANDLER JP, 1983, STEPT QUANTUM CHEM P
  • [4] CELL-PROLIFERATION AND DIFFERENTIATION IN SQUAMOUS CANCER
    DISCHE, S
    SAUNDERS, MI
    BENNETT, MH
    WILSON, GD
    MCNALLY, NJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1989, 15 (01) : 19 - 23
  • [5] FLOW CYTOMETRIC MEASUREMENT OF TOTAL DNA CONTENT AND INCORPORATED BROMODEOXYURIDINE
    DOLBEARE, F
    GRATZNER, H
    PALLAVICINI, MG
    GRAY, JW
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1983, 80 (18): : 5573 - 5577
  • [6] AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS
    MARQUARDT, DW
    [J]. JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02): : 431 - 441
  • [7] RICCARDI A, 1988, CANCER RES, V48, P6238
  • [8] AN IMPROVED METHOD FOR THE IMMUNOCYTOCHEMICAL DETECTION OF BROMODEOXYURIDINE LABELED NUCLEI USING FLOW-CYTOMETRY
    SCHUTTE, B
    REYNDERS, MMJ
    VANASSCHE, CLMVJ
    HUPPERETS, PSGJ
    BOSMAN, FT
    BLIJHAM, GH
    [J]. CYTOMETRY, 1987, 8 (04): : 372 - 376
  • [9] Steel G.G., 1977, GROWTH KINETICS TUMO
  • [10] EVALUATION OF FLOW CYTOMETRIC METHODS FOR DETERMINING POPULATION POTENTIAL DOUBLING TIMES USING CULTURED-CELLS
    TERRY, NHA
    WHITE, RA
    MEISTRICH, ML
    CALKINS, DP
    [J]. CYTOMETRY, 1991, 12 (03): : 234 - 241