FULLY SLOTLESS TURBOGENERATORS

被引:13
作者
SPOONER, E
机构
[1] ROLLS ROYCE & ASSOC LTD,POB 31,DERBY,ENGLAND
[2] CENT ELECT RES LABS,KELVIN AVE,LEATHERHEAD,SURREY,ENGLAND
来源
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON | 1973年 / 120卷 / 12期
关键词
D O I
10.1049/piee.1973.0310
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is shown that the constraints restricting the choice of rotor length and diameter in a turbogenerator are relaxed, and much higher airgap flux densities are possible if a fully slotless construction is employed. Capacities about three times greater than can be achieved with conventional machines are possible, and there is wide scope for optimizing the dimensions and loadings of machines of present-day ratings; e. g. a 660 Mw slotless machine could show savings of about 2 Mw in losses, 4 m in length and 150 t in mass and would have reactances more suited to stable operation. Gas or liquid cooling of the active parts could be employed without special problems.
引用
收藏
页码:1507 / 1518
页数:12
相关论文
共 9 条
[1]  
ADKINS B, 1964, GENERAL THEORY ELECT
[2]  
AICHHOLZER G, ELEKTROTECH MACHINEN, V89, P1
[3]  
[Anonymous], ELECTROMAGNETIC FIEL
[4]   AIRGAP WINDINGS FOR LARGE TURBOGENERATORS [J].
DAVIES, EJ .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1971, 118 (3-4) :529-&
[5]  
HAM AC, PHYS B, V20, P474
[6]   GOODNESS OF A MACHINE [J].
LAITHWAITE, ER .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1965, 112 (03) :538-+
[7]   CALCULATION OF MACHINE END-WINDING INDUCTANCES WITH SPECIAL REFERENCE TO TURBOGENERATORS [J].
LAWRENSON, PJ .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (06) :1129-+
[8]  
REECE ABJ, TO BE PUBLISHED
[9]  
1965, Patent No. 52449