PREMIXED INSULIN PREPARATIONS IN PEN SYRINGES MAINTAIN GLYCEMIC CONTROL AND ARE PREFERRED BY PATIENTS

被引:29
作者
DUNBAR, JM [1 ]
MADDEN, PM [1 ]
GLEESON, DT [1 ]
FIAD, TM [1 ]
MCKENNA, TJ [1 ]
机构
[1] ST VINCENTS HOSP,CTR DIABET,DEPT ENDOCRINOL & DIABET MELLITUS,DUBLIN 4,IRELAND
关键词
D O I
10.2337/diacare.17.8.874
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To examine the impact on glycemic control of substituting a range of premixed insulins for the standard treatment with patient-mixed insulin combinations. In addition, a pen-type syringe was substituted for the conventional insulin syringe, and the patients' preference was ascertained at the end of the study. RESEARCH DESIGN AND METHODS - Before the study, all patients had maintained a constant insulin dosage for 2 months. For the first month of the study, all patients were encouraged to make any adjustment in insulin dosage required to optimize control. Twenty-seven patients participated in the study. At the end of the first month, patients were randomized either to change to premixed insulins or to continue with self-mixed insulins for 2 months. At the end of the 2-month period, participants changed to the alternative regime for a further 2 months. Glycemic control was measured by assessment of glycosylated hemoglobin levels at the start of the study and after each 2-month period of the study. In addition, during the 1-month run-in period and during both 2-month study periods, a seven-point blood glucose profile was obtained extending from before breakfast to just before retiring for sleep. RESULTS - Glycosylated hemoglobin levels were unchanged throughout the duration of the study. Similarly, there were no systematic changes in individual seven-point blood glucose profiles. The frequency of hypoglycemic reactions was similar on patient-mixed and premixed insulin programs. However, 83% of patients expressed a preference for premixed insulins. A similar percentage regarded pen-type insulin syringes to be preferable to the conventional syringe. CONCLUSIONS - Glycemic control was similar on patient-mixed and premixed insulins, and patients had a marked preference for premixed insulins delivered in a pen-type syringe over conventional insulin therapy. Premixed insulin delivered by a pen-type syringe promises to ease the burden of daily injections for many diabetic patients.
引用
收藏
页码:874 / 878
页数:5
相关论文
共 11 条
  • [1] DOSAGE ACCURACY OF SELF-MIXED VS PREMIXED INSULIN
    BELL, DSH
    CLEMENTS, RS
    PERENTESIS, G
    RODDAM, R
    WAGENKNECHT, L
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (11) : 2265 - 2269
  • [2] CORCORAN JS, 1985, DIABETIC MED, V3, P246
  • [3] USE OF PREMIXED INSULIN AMONG THE ELDERLY - REDUCTION OF ERRORS IN PATIENT PREPARATION OF MIXTURES
    COSCELLI, C
    CALABRESE, G
    FEDELE, D
    PISU, E
    CALDERINI, C
    BISTONI, S
    LAPOLLA, A
    MAURI, MG
    ROSSI, A
    ZAPPELLA, A
    [J]. DIABETES CARE, 1992, 15 (11) : 1628 - 1630
  • [4] CUCINOTTA D, 1991, DIABETES METAB, V17, P49
  • [5] AN EXACT TEST FOR COMPARING MATCHED PROPORTIONS IN CROSSOVER DESIGNS
    GART, JJ
    [J]. BIOMETRIKA, 1969, 56 (01) : 75 - &
  • [6] MONTWILL J, 1993, J BIOMED SCI, V4, P17
  • [7] NOLTE MS, 1992, ENDOCRIN METAB CLIN, V21, P281
  • [8] PATERSON K, 1992, DIABETIC MED, V7, P684
  • [9] PICKUP JC, 1991, TXB DIABETES, P384
  • [10] Roland J M, 1984, Diabet Med, V1, P51