PRACTICAL LIMITATIONS OF THE DELTATRAC INDIRECT CALORIMETER

被引:7
作者
VOHRA, SB [1 ]
KEEGAN, MA [1 ]
CAMPBELL, IT [1 ]
MCGUINNESS, K [1 ]
机构
[1] UNIV MANCHESTER,WITHINGTON HOSP,DEPT ANAESTHESIS,MANCHESTER M20 8LR,LANCS,ENGLAND
关键词
D O I
10.1016/S0261-5614(95)80013-1
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 [营养与食品卫生学];
摘要
Indirect calorimetry is used to assess energy requirements. The Deltatrac Metabolic Monitor is a relatively inexpensive indirect calorimeter which uses a 'fixed' flow of ambient air to collect expired air. Only oxygen and carbon dioxide concentrations are measured and the 'fixed flow' is assumed in the calculation of oxygen consumption (VO2) and carbon dioxide production (VO2). Using inert gas dilution we have studied the effect on VO2, and on the variability in VO2, of changing and lengthening the 1.77 m length of 35 mm tubing supplied with the instrument to collect expired air, and of using a mask to collect expired air instead of the manufacturer's hood. One would anticipate that changing the tubing could cause a change in resistance to gas flow and thus affect the true flow rate. This would alter the gas concentrations seen by the analysers, but the 'fixed flow' would still be assumed so the results would be in error. Adding extra lengths of manufacturers tubing caused an apparent rise in VO2 of 0.36%/m of tubing added, and using 22 mm tubing instead of the manufacturer's 35 mm tubing increased VO2 by 0.42% for each 10 cm of tubing added. Using the mask to collect expired air instead of the canopy VO2 was higher, possibly due to the energy cost of holding the mask, and was more variable, probably because of poorer mixing of the expired air. To measure VO2 using a mask with the same precision as a 10 min measurement made with the hood would entail measuring VO2 for 14.5 min. The methods used to collect expired air (mask or canopy, length and type of tubing) when measuring metabolic rate with the Deltatrac do affect the results obtained but these effects are small and predictable.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 9 条
[1]
Takala, Keinanen, Vaisanen, Aarno, Measurement of gas exchange in intensive care: Laboratory and clinical validation of a new device, Crit Care Med, 17, pp. 1041-1047, (1989)
[2]
Weissman, Sardor, Kemper, In vitro evaluation of a compact metabolic measurement instrument, PEN, 14, pp. 216-221, (1990)
[3]
Cooper, MacLean, Taylor, An evaluation of the Deltatrac indirect calorimeter by gravimetric injection and alcohol burning, Clin Phys Physiol Meas, 12, pp. 333-341, (1991)
[4]
Phang, Rich, Ronco, A validation and comparison study of two metabolic monitors, PEN, 14, pp. 259-261, (1990)
[5]
Garrow, Webster, A computer controlled indirect calorimeter for the measurement of energy expenditure in one or two subjects simultaneously, Hum Nut: Clin Nutr, 40 C, pp. 315-321, (1986)
[6]
Newell, Kappagoda, Linden, Method for continuous measurement of carbon dioxide output, J Appl Physiol, 41, pp. 810-815, (1976)
[7]
Lister, Hoffman, Rudolph, Measurement of oxygen consumtion: assessing the accuracy of a method, J Appl Physiol, 43, pp. 916-919, (1977)
[8]
Damask, Weissman, Askanazi, Hyman, Rosenbaum, Kinney, A systematic method for validation of gas exchange measurements, Anesthesiology, 57, pp. 213-218, (1982)
[9]
McGuiness, Childs, Development of an indirect calorimeter for use with infants and young children, Clinical Physics and Physiological Measurement, 12, pp. 343-351, (1991)