REDUCTION OF SOME SELECTED SPECTRAL INTERFERENCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:43
作者
TITTES, W
JAKUBOWSKI, N
STUWER, D
TOLG, G
机构
[1] INST SPEKTROCHEM & ANGEW SPEKT,POSTFACH 101352,D-44013 DORTMUND,GERMANY
[2] UNIV DORTMUND,FACHBEREICH CHEM,D-44221 DORTMUND,GERMANY
关键词
HIGH RESOLUTION; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; DESOLVATION; SPECTRAL INTERFERENCE; CHLORINE;
D O I
10.1039/ja9940901015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reduction of spectral interferences has been investigated and both aerosol desolvation and the utilization of high mass resolution have been applied in order to improve detection limits for V, Cr, Ga, Ge and As, which are subject to interferences by polyatomic ions in solutions containing Cl. Experiments with a laboratory-made quadrupole ICP-MS have been performed in order to optimize the desolvation parameters. Ion signals corresponding to ClO+ and ClOH+ are reduced by more than one order of magnitude if appropriate heating and cooling temperatures are chosen. A reduction in polyatomic ions like ClO2+, Cl2+ and ArCl+ by using desolvation was also observed. With the prototype of a new double-focusing ICP-MS system from Finnigan MAT, Bremen, Germany, operated in the low resolution mode, the detection limits with desolvation have been determined and were found to be up to 2 orders of magnitude lower compared with measurements without desolvation. The detection limit (3s) for V in 0.4 mol l-1 HCl was reduced from 25 to 1 ng ml-1. High mass resolution improved the detection limits for V, Cr and Ga in HCl by up to 4 orders of magnitude compared with measurements in the low resolution mode (2 pg ml-1 for V in 0.4 mol 1(-1) HCl), and lowest detection limits have been obtained with the combination of desolvation and high mass resolution (0.6 pg ml-1 for V in 0.4 mol l-1 HCl).
引用
收藏
页码:1015 / 1020
页数:6
相关论文
共 32 条
[1]   MEASUREMENT OF VANADIUM, NICKEL, AND ARSENIC IN SEAWATER AND URINE REFERENCE MATERIALS BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH CRYOGENIC DESOLVATION [J].
ALVES, LC ;
ALLEN, LA ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2468-2471
[2]   REDUCTION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY CRYOGENIC DESOLVATION [J].
ALVES, LC ;
WIEDERIN, DR ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1164-1169
[3]   INDUCTIVELY COUPLED PLASMA AS AN ION-SOURCE FOR HIGH-RESOLUTION MASS-SPECTROMETRY [J].
BRADSHAW, N ;
HALL, EFH ;
SANDERSON, NE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :801-803
[4]   METHOD FOR INVESTIGATING SIZE DISTRIBUTIONS OF AQUEOUS DROPLETS IN THE RANGE 0.5-10 MU-M PRODUCED BY PNEUMATIC NEBULIZERS [J].
CRESSER, MS ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (02) :73-79
[5]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[6]   EFFECT OF ORGANIC-SOLVENTS AND MOLECULAR GASES ON POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EVANS, EH ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :425-429
[7]  
GIESSMANN U, 1993, 2ND REG S MASS VERF
[8]   ANION-EXCHANGE FOR THE DETERMINATION OF ARSENIC AND SELENIUM BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GOOSSENS, J ;
MOENS, L ;
DAMS, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :921-926
[9]   ANION-EXCHANGE FOR THE ELIMINATION OF SPECTRAL INTERFERENCES CAUSED BY CHLORINE AND SULFUR IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GOOSSENS, J ;
DAMS, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1167-1171
[10]  
HABFAST K, 1968, MASSENSPEKTROMETRIE, P74