PERIPHERAL NEUROLOGIC ABNORMALITIES AMONG ROOFING WORKERS - SENTINEL CASE AND CLINICAL SCREENING

被引:5
作者
HERBERT, R
GERR, F
LUO, J
HARRISABBOTT, D
LANDRIGAN, PJ
机构
[1] MT SINAI SCH MED,DIV ENVIRONM & OCCUPAT MED,NEW YORK,NY
[2] EMORY UNIV,SCH PUBL HLTH,DIV ENVIRONM & OCCUPAT HLTH,ATLANTA,GA
来源
ARCHIVES OF ENVIRONMENTAL HEALTH | 1995年 / 50卷 / 05期
关键词
D O I
10.1080/00039896.1995.9935966
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Peripheral neuropathy developed in a 52-y-old roofer who was exposed to multiple solvents in one-ply roofing systems. Forty roofers who were exposed to various roofing systems were assessed by symptoms, occupational history, standardized physical examination, and measurement of vibrotactile thresholds of the upper and lower extremities. After exclusion of roofers who were predisposed to peripheral neuropathy, we defected abnormal vibrotactile thresholds in 42% (p < .001) of roofers' dominant toes and in 36% (p < .001) of roofers' nondominant toes; fewer roofers had abnormal sensory physical examinations or reported neuritic symptoms. Roofing workers may be at increased risk of peripheral neuropathy, perhaps resulting from exposure to solvents-particularly n-hexane, associated with one-ply roofing systems.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 18 条
[1]  
BAKER EL, 1988, ANNU REV PUBL HEALTH, V9, P223
[2]   THE NEUROTOXICITY OF INDUSTRIAL SOLVENTS - A REVIEW OF THE LITERATURE [J].
BAKER, EL ;
SMITH, TJ ;
LANDRIGAN, PJ .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1985, 8 (03) :207-217
[3]  
BROWN SK, 1987, AM IND HYG ASSOC J, V48, P478, DOI 10.1080/15298668791385075
[4]   PHOTOTOXIC KERATOCONJUNCTIVITIS FROM COAL-TAR PITCH VOLATILES [J].
EMMETT, EA ;
STETZER, L ;
TAPHORN, B .
SCIENCE, 1977, 198 (4319) :841-842
[5]  
EMMETT EA, 1986, OCCUP MED, V1, P307
[6]  
FLEISS JL, 1981, STAT METHODS RATES P, P13
[7]   VIBROTACTILE THRESHOLD MEASUREMENT FOR DETECTING NEUROTOXICITY - RELIABILITY AND DETERMINATION OF AGE-STANDARDIZED AND HEIGHT-STANDARDIZED NORMATIVE VALUES [J].
GERR, F ;
HERSHMAN, D ;
LETZ, R .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1990, 45 (03) :148-154
[8]   COMPARISON OF VIBROTACTILE THRESHOLDS WITH PHYSICAL-EXAMINATION AND ELECTROPHYSIOLOGICAL ASSESSMENT [J].
GERR, F ;
LETZ, R ;
HERSHMAN, D ;
FARRAYE, J ;
SIMPSON, D .
MUSCLE & NERVE, 1991, 14 (11) :1059-1066
[9]  
GERR F, 1992, ENV OCCUPATIONAL MED
[10]  
GERR FE, 1988, BRIT J IND MED, V45, P635