CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US

被引:164
作者
HUSTON, J
LEWIS, BD
WIEBERS, DO
MEYER, FB
RIEDERER, SJ
WEAVER, AL
机构
[1] MAYO CLIN & MAYO FDN,DEPT BIOSTAT,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT NEUROSURG,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT NEUROL,ROCHESTER,MN 55905
关键词
CAROTID ARTERIES; MR; US; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; VASCULAR STUDIES;
D O I
10.1148/radiology.186.2.8421731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective blinded comparison of two-dimensional (2D) time-of-flight (TF) magnetic resonance (MR) angiography and color duplex flow ultrasound (US) with conventional angiography as a standard of reference was performed in 50 patients with hemispheric ischemic symptoms. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were utilized for maximum-intensity-projection (MIP) images and conventional angiograms. While the 2D TF MIP technique overrepresented the degree of stenosis in the internal carotid arteries, it matched the performance of color duplex flow US as measured by means of receiver operating characteristic curves. A signal void on the MIP images corresponded to a 70% or greater internal carotid artery stenosis in 17 of 20 arteries. At its current state of development, the accuracy of 2D TF MR angiography equals that of US in characterizing the degree of carotid stenosis but cannot be considered a replacement for conventional angiography.
引用
收藏
页码:339 / 344
页数:6
相关论文
共 17 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] Barnett H. J. M., 1991, NEW ENGL J MED, V325, P445
  • [4] BLACKSHEAR WM, 1979, SURGERY, V86, P698
  • [5] MR ANGIOGRAPHY WITH OBLIQUE GRADIENT-RECALLED ECHO TECHNIQUE
    BROWN, DG
    RIEDERER, SJ
    JACK, CR
    FARZANEH, F
    EHMAN, RL
    [J]. RADIOLOGY, 1990, 176 (02) : 461 - 466
  • [6] OBSERVER VARIABILITY IN EVALUATING EXTRA-CRANIAL CAROTID-ARTERY STENOSIS
    CHIKOS, PM
    FISHER, LD
    HIRSCH, JH
    HARLEY, JD
    THIELE, BL
    STRANDNESS, DE
    [J]. STROKE, 1983, 14 (06) : 885 - 892
  • [7] COUSINS JP, 1989, AM J NEURORADIOL, V10, P921
  • [8] EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    WALLNER, B
    BAJAKIAN, R
    KLEEFIELD, J
    KENT, C
    SKILLMAN, JJ
    MENDEL, JB
    ATKINSON, DJ
    [J]. RADIOLOGY, 1990, 177 (01) : 45 - 50
  • [9] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    FRAM, EK
    KELLER, PJ
    BIRD, CR
    HODAK, JA
    FLOM, RA
    [J]. RADIOLOGY, 1992, 182 (03) : 761 - 768
  • [10] MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS
    KELLER, PJ
    DRAYER, BP
    FRAM, EK
    WILLIAMS, KD
    DUMOULIN, CL
    SOUZA, SP
    [J]. RADIOLOGY, 1989, 173 (02) : 527 - 532