SILICON TISSUE-ASSAYS IN NONAUGMENTED CADAVERIC PATIENTS - IS THERE A BASE-LINE LEVEL

被引:35
作者
EVANS, GRD
SLEZAK, S
RIETERS, M
BERCOWY, GM
机构
[1] UNIV MARYLAND HOSP, DIV PLAST & RECONSTRUCT SURG, BALTIMORE, MD 21201 USA
[2] UNIV MARYLAND, SCH MED, BALTIMORE, MD 21201 USA
关键词
D O I
10.1097/00006534-199405000-00001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Microscopic silicone in various tissues in the bodies of females with breast implants has led to the possible incrimination of these implants with connective-tissue disorders. Current technology precludes accurate silicone measurements, but ah compounds containing the element silicon (which would include silicone) may be measured accurately. Direct positive correlations of silicon assays with silicone measured levels were confirmed by adding known amounts of silicone oil as a control. With the ubiquitous nature of organosilicons (food containers, syringes, etc.), we hypothesized that baseline silicon levels could be detected in tissues of cadavers without silicone breast augmentation. Ten cadavers were examined. Tissue samples were derived from subcutaneous fat, nipple, breast tissue, liver, spleen, and axillary nodes. Nine of 10 cadavers had silicon levels in various tissues. Measurements were performed by direct current atomic emission spectroscopy. The baseline data were compared with those from four augmented patients who underwent capsulectomies and implant removal. Silicon levels were fivefold higher in the augmented patients than in the nonaugmented cadavers. No difference in levels was noted if the patient had an intact or ruptured implant and/or was symptomatic versus asymptomatic for immunologic disease. This study was designed to measure baseline silicon levels in the normal population. It also has established an accurate level of measurement of tissue silicone.
引用
收藏
页码:1117 / 1122
页数:6
相关论文
共 49 条
[1]  
[Anonymous], 1989, MERCK INDEX
[2]   SILICONE GRANULOMA FOLLOWING CLOSED CAPSULOTOMY OF MAMMARY PROSTHESIS [J].
APESOS, J ;
POPE, TL .
ANNALS OF PLASTIC SURGERY, 1985, 14 (05) :403-406
[4]  
ARKLES B, 1983, CHEMTECH, V13, P542
[5]   POSITIVE IDENTIFICATION OF SILICONE IN HUMAN MAMMARY CAPSULAR TISSUE [J].
BAKER, JL ;
LEVIER, RR ;
SPIELVOGEL, DE .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1982, 69 (01) :56-60
[6]   SILICONE-INDUCED HUMAN ADJUVANT DISEASE [J].
BALDWIN, CM ;
KAPLAN, EN .
ANNALS OF PLASTIC SURGERY, 1983, 10 (04) :270-273
[7]  
Ballantyne D L Jr, 1965, Plast Reconstr Surg, V36, P330, DOI 10.1097/00006534-196509000-00005
[8]   5 YEARS EXPERIENCE OF BREAST AUGMENTATION USING SILICONE GEL PROSTHESES WITH EMPHASIS ON CAPSULE SHRINKAGE [J].
BRANDT, B ;
BREITING, V ;
CHRISTENSEN, L ;
NIELSEN, M ;
THOMSEN, JL .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1984, 18 (03) :311-316
[9]  
BRODY GS, 1988, JAMA-J AM MED ASSOC, V260, P3008, DOI 10.1001/jama.1988.03410200052023
[10]   HUMAN ADJUVANT DISEASE FOLLOWING AUGMENTATION MAMMOPLASTY [J].
BROZENA, SJ ;
FENSKE, NA ;
CRUSE, CW ;
ESPINOZA, CG ;
VASEY, FB ;
GERMAIN, BF ;
ESPINOZA, LR .
ARCHIVES OF DERMATOLOGY, 1988, 124 (09) :1383-1386