EFFECT OF RESPIRATION ON DOPPLER PARAMETERS OF NORMAL TRICUSPID PORCINE BIOPROSTHETIC VALVES

被引:2
作者
COSYNS, B
VANCAMP, G
FRIART, A
VANDENBOSSCHE, JL
机构
[1] Cardiology Department, Saint-Pierre University Hospital, Brussels
[2] Cardiology Department, Tivoli Hospital, La Louvière
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1995年 / 11卷 / 01期
关键词
DOPPLER; INFLUENCE OF RESPIRATION; TRICUSPID PORCINE BIOPROSTHETIC VALVES; ECHOCARDIOGRAPHY;
D O I
10.1007/BF01148954
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Doppler indexes of tricuspid porcine bioprosthetic valves were evaluated in twelve patients without clinical and two-dimensional echocardiographic evidence of valve dysfunction. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. All the Doppler measurements were compared during inspiration and expiration. During inspiration peak velocity, peak gradient and mean gradient (1.52 +/- 0.28 m/s; 9.7 +/- 3.05 mmHg; 4.07 +/- 1.16 mmHg) were significantly higher than during expiration (1.28 +/- 0.8 m/s; 6.58 +/- 2.7 mmHg; 2.98 +/- 1.13 mmHg; p < 0.01) but pressure half time was not significantly different (122 +/- 62 ms versus 134 +/- 75 ms; p > 0.05). Inspiratory range of peak velocities, peak gradients, mean gradients and pressure half times were respectively 0.8-2.04 m/s; 4.9-16.6 mmHg; 1.2-7.2 mmHg; 42-340 ms while expiratory range of values was 0.8-1.93 m/s; 2.6-15 mmHg; 1.1-5.7 mmHg; 46-345 ms. These data suggest that even very long pressure half times do not indicate valve dysfunction. This study demonstrates that large variation of Doppler parameters are present during respiration and could produce inaccuracy in the assessment of bioprostheses in tricuspid position if they are not taken in consideration.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 13 条
[1]   PULMONARY BLOOD FLOW AND VENOUS RETURN DURING SPONTANEOUS RESPIRATION [J].
BRECHER, GA ;
HUBAY, CA .
CIRCULATION RESEARCH, 1955, 3 (02) :210-214
[2]   ACCURACY OF DOPPLER ECHOCARDIOGRAPHY IN DETECTING AND QUANTIFYING TRICUSPID STENOSIS AND OBSTRUCTED TRICUSPID PROSTHESES [J].
FAWZY, ME ;
MERCER, EN ;
DUNN, B ;
ALAMRI, M ;
ANDAYA, W ;
DURAN, C .
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (05) :312-317
[3]   EFFECT OF RESPIRATION ON VENOUS RETURN AND STROKE VOLUME IN CARDIAC TAMPONADE [J].
GUNTHEROTH, WG ;
MORGAN, BC ;
MULLINS, GL .
CIRCULATION RESEARCH, 1967, 20 (04) :381-+
[4]  
LEWIS BS, 1979, EUR J CARDIOL, V10, P89
[5]   TRICUSPID STENOSIS IN PROSTHETIC VALVE ENDOCARDITIS - DIAGNOSIS BY DOPPLER ECHOCARDIOGRAPHY [J].
LEWIS, JF ;
PENISTON, RL ;
RANDALL, OS ;
SPENCER, J ;
SHELLER, LM .
CHEST, 1987, 91 (02) :276-277
[6]  
MARTI V, 1991, AM J CARDIOL, P307
[7]  
PANIDIS IP, 1986, J AM COLL CARDIOL, P8317
[8]   USEFULNESS OF DOPPLER ECHOCARDIOGRAPHY IN DETECTING TRICUSPID-VALVE STENOSIS [J].
PEREZ, JE ;
LUDBROOK, PA ;
AHUMADA, GG .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (05) :601-603
[9]  
PYE M, 1990, BRIT HEART J, V63, P41
[10]   REFERENCE VALUES AND REPRODUCIBILITY OF DOPPLER ECHOCARDIOGRAPHY IN THE ASSESSMENT OF THE TRICUSPID-VALVE AND RIGHT VENTRICULAR DIASTOLIC FUNCTION IN NORMAL SUBJECTS [J].
PYE, MP ;
PRINGLE, SD ;
COBBE, SM .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (04) :269-273