DETECTION OF THE FETAL ECG DURING LABOR BY AN INTRAUTERINE PROBE

被引:19
作者
RANDALL, NJ
STEER, PJ
SUTHERLAND, IA
机构
[1] Bio-Medical Technology Group, Department of Obstetrics and Gynaecology, St Mary's Hospital Medical School, London W2 1PG, United Kingdom
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1988年 / 10卷 / 02期
关键词
BIOLOGICAL MATERIALS - Cardiovascular System - BIOMEDICAL EQUIPMENT - Microelectrodes - BIOSENSORS - Design;
D O I
10.1016/0141-5425(88)90093-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of detecting the fetal ECG (FECG) from within the uterus in labour by a technique which is non-invasive to the fetus has been investigated. The design of a special multi-electrode flexible probe has demonstrated that the FECG can be obtained with signal amplitudes of 20-300 mu V and a success rate similar to that of the scalp electrode. Under favourable conditions very large signals can be detected in utero compared to a scalp electrode, but average signal amplitudes are lower. The probe is suitable as a carrier for other sensors such as pressure and temperature transducers. Currently, simultaneous FECG and intrauterine pressure measurement using a commercially available transducer within the same probe has been achieved.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 9 条
[1]   VERY EARLY NEONATAL SEIZURE RATE - A POSSIBLE EPIDEMIOLOGICAL INDICATOR OF THE QUALITY OF PERINATAL-CARE [J].
DENNIS, J ;
CHALMERS, I .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (06) :418-426
[2]  
GATZKE RD, 1974, BIOMEDICAL TECHNOLOG
[3]  
GEDDES LA, 1972, ELECTRODES MEASUREME, pCH1
[4]   EVALUATION OF CONTINUOUS FETAL HEART-RATE MONITORING IN HIGH-RISK PREGNANCY [J].
HAVERKAMP, AD ;
THOMPSON, HE ;
MCFEE, JG ;
CETRULO, C .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 125 (03) :310-320
[5]   CONTROLLED TRIAL OF THE DIFFERENTIAL EFFECTS OF INTRAPARTUM FETAL MONITORING [J].
HAVERKAMP, AD ;
ORLEANS, M ;
LANGENDOERFER, S ;
MCFEE, J ;
MURPHY, J ;
THOMPSON, HE .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1979, 134 (04) :399-412
[6]   THE DUBLIN RANDOMIZED CONTROLLED TRIAL OF INTRAPARTUM FETAL HEART-RATE MONITORING [J].
MACDONALD, D ;
GRANT, A ;
SHERIDANPEREIRA, M ;
BOYLAN, P ;
CHALMERS, I .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 152 (05) :524-539
[7]  
RANDALL NJ, 1985, 14 7 P ICMBE ICMP, V1, P495
[8]   CONTROLLED TRIAL OF FETAL INTENSIVE-CARE [J].
RENOU, P ;
CHANG, A ;
ANDERSON, I ;
WOOD, C .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 126 (04) :470-476
[9]   A CONTROLLED TRIAL OF FETAL HEART-RATE MONITORING IN A LOW-RISK OBSTETRIC POPULATION [J].
WOOD, C ;
RENOU, P ;
OATS, J ;
FARRELL, E ;
BEISCHER, N ;
ANDERSON, I .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 141 (05) :527-534