THE CT SCANNER AS A THERAPY MACHINE

被引:28
作者
IWAMOTO, KS
NORMAN, A
KAGAN, AR
WOLLIN, M
OLCH, A
BELLOTTI, J
INGRAM, M
SKILLEN, RG
机构
[1] UNIV CALIF LOS ANGELES,DEPT RADIAT ONCOL,WARREN HALL,900 VET AVE,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,DEPT RADIOL SCI,LOS ANGELES,CA 90024
[3] UNIV CALIF LOS ANGELES,JONSSON COMPREHENS CANC CTR,LOS ANGELES,CA 90024
[4] KAISER PERMANENTE,DEPT RADIAT THERAPY,LOS ANGELES,CA
[5] HUNTINGTON MED RES INST,PASADENA,CA
关键词
CT SCANNER; X-RAY THERAPY;
D O I
10.1016/0167-8140(90)90034-T
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Many tumors in the brain and in other tissues can be delineated precisely in images obtained with a CT scanner. After the scan is obtained the patient is taken to another room for radiation therapy and is positioned in the beam with the aid of external markers, simulators or stereotactic devices. This procedure is time consuming and subject to error when precise localization of the beam is desired. The CT scanner itself, with the addition of a collimator, is capable of delivering radiation therapy with great precision without the need for external markers. The patient can be scanned and treated on the same table, the isocenter of the beam can be placed precisely in the center of the lesion, the beam can be restricted to just those planes in which the lesion appears, several arcs can be obtained by simply tilting the gantry, and the position of the patient in the beam can be monitored continuously during therapy. We describe here the properties of the CTX, the CT scanner modified for therapy.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 6 条
  • [1] CASSADY AE, THESIS UCLA
  • [2] RADIATION-DOSE ENHANCEMENT THERAPY WITH IODINE IN RABBIT VX-2 BRAIN-TUMORS
    IWAMOTO, KS
    COCHRAN, ST
    WINTER, J
    HOLBURT, E
    HIGASHIDA, RT
    NORMAN, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 1987, 8 (02) : 161 - 170
  • [3] RELATIVE BIOLOGICAL EFFECTIVENESS OF I125 IN THE INDUCTION OF MICRONUCLEI IN HUMAN PERIPHERAL-BLOOD LYMPHOCYTES
    KWAN, DK
    KAGAN, AR
    NORMAN, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 1985, 4 (02) : 163 - 166
  • [4] LEKSELL D G, 1987, Neurological Research, V9, P60
  • [5] RADIATION-DOSE ENHANCEMENT IN TUMORS WITH IODINE
    MELLO, RS
    CALLISEN, H
    WINTER, J
    KAGAN, AR
    NORMAN, A
    [J]. MEDICAL PHYSICS, 1983, 10 (01) : 75 - 78
  • [6] HEAVY CHARGED-PARTICLE STEREOTACTIC RADIOSURGERY - CEREBRAL-ANGIOGRAPHY AND CT IN THE TREATMENT OF INTRACRANIAL VASCULAR MALFORMATIONS
    PHILLIPS, MH
    FRANKEL, KA
    LYMAN, JT
    FABRIKANT, JI
    LEVY, RP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (02): : 419 - 426