LONG-TERM RESULTS OF SUTURELESS PHACOEMULSIFICATION WITH IMPLANTATION OF A 7-MM POLYMETHYL METHACRYLATE INTRAOCULAR-LENS

被引:27
作者
BUSIN, M
SCHMIDT, J
KOCH, J
SPITZNAS, M
机构
[1] University Eye Hospital, Bonn
关键词
D O I
10.1001/archopht.1993.01090030051038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
In an attempt to minimize postoperative astigmatism while retaining the advantages of implanting intraocular lenses with large optics, sutureless phacoemulsification with implantation of a 7-mm polymethyl methacrylate intraocular lens was performed through a modified scleral tunnel in 100 consecutive patients. Visual and keratometric results, as well as complications, were recorded during a follow-up period of 12 months. Average uncorrected visual acuity improved from 20/153 before surgery to 20/66 as early as 1 week after surgery. Average best corrected visual acuity improved from 20/86 before surgery to 20/39 as early as 1 week after surgery. No significant changes in visual acuity were recorded thereafter. The absolute value of keratometric astigmatism was not increased significantly at any postoperative examination time. The induced cylinder shifted from 1.26 diopters x74.40-degrees at 1 week to 1.22 D x1.50-degrees at 1 month after surgery, without further relevant changes thereafter. Mean (+/-SD) endothelial cell loss was 7.2%+/-6.1% at 1 month and 12.2%+/-5.4% at 6 months after surgery. Corneal thickness was not increased significantly at any postoperative examination time. Implantation of intraocular lenses with large optics through a scleral tunnel allows quick visual rehabilitation as well as early stability of refraction.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 40 条
[1]   LONGITUDINAL-STUDY OF POSTOPERATIVE ASTIGMATISM [J].
AXT, JC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (04) :381-388
[2]   EFFECTS OF THE SHEARING POSTERIOR CHAMBER INTRAOCULAR-LENS ON THE CORNEAL ENDOTHELIUM [J].
AZEN, SP ;
HURT, A ;
STEEL, D ;
WILSON, J ;
REINIG, J ;
BERNSTEIN, J ;
BEDI, M ;
SMITH, RE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 95 (06) :798-802
[3]  
Brauweiler HP, 1991, OPHTHALMOCHIRURGIE, V3, P75
[4]   KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES [J].
BRINT, SF ;
OSTRICK, DM ;
BRYAN, JE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) :32-36
[5]   COMPARISON OF POSTOPERATIVE ASTIGMATISM WITH INCISIONS OF VARYING LENGTH CLOSED WITH HORIZONTAL SUTURES AND WITH NO SUTURES [J].
BUZARD, KA ;
SHEARING, SP .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :734-739
[6]  
Colvard DM, 1981, AM INTRAOCULAR IMPLA, V7, P334
[7]   RESULTS OF THE INTERCAPSULAR TECHNIQUE WITH THE IOGEL LENS [J].
CONDON, PI ;
BARRETT, GD ;
KINSELLA, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05) :495-503
[8]   CREATION OF A NO-STITCH CATARACT INCISION [J].
FISH, JR .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :713-715
[9]   COMPARISON OF THE UNWANTED OPTICAL-IMAGES PRODUCED BY 6-MM AND 7-MM INTRAOCULAR LENSES [J].
FRIEDBERG, HL ;
KLINE, OR ;
FRIEDBERG, AH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05) :541-544
[10]   EARLY RESULTS OF 500 CASES OF NO-STITCH CATARACT-SURGERY [J].
GRABOW, HB .