CONTACT B-SCAN ECHOGRAPHY IN THE ASSESSMENT OF OPTIC-NERVE CUPPING

被引:13
作者
DARNLEYFISCH, DA [1 ]
BYRNE, SF [1 ]
HUGHES, JR [1 ]
PARRISH, RK [1 ]
FEUER, WJ [1 ]
机构
[1] UNIV MIAMI,SCH MED,BASCOM PALMER EYE INST,DEPT OPHTHALMOL,POB 016880,MIAMI,FL 33101
关键词
D O I
10.1016/S0002-9394(14)75579-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We determined the reliability of high-resolution contact B-scan echography for estimating the optic cup size in 56 eyes of 28 patients with glaucoma or ocular hypertension. Two trained observers independently evaluated horizontal and vertical cup/disk ratios in stereophotographs, and two skilled echographers independently estimated optic cup size in photoechograms in a masked fashion. The reliability of echographic interpretation varied (kappa 0.29 to 0.71), but it always exceeded that expected by chance alone, even for cups of 0.3 disk diameter or less. Subtly saucer-shaped cups (three of 50 eyes) and deep cups with intact neuroretinal rims (two of 50 eyes) were misenterpreted echographically. High-resolution contact B-scan echography may provide a useful and reliable estimate of the optic cup size in eyes with opaque media.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 13 条
[1]  
AIRAKSINEN PJ, 1985, AM J OPHTHALMOL, V99, P1
[2]  
BENGTSSON B, 1976, ACTA OPHTHALMOL, V54, P804
[3]   THE AREA OF THE NEURORETINAL RIM OF THE OPTIC-NERVE IN NORMAL EYES [J].
BRITTON, RJ ;
DRANCE, SM ;
SCHULZER, M ;
DOUGLAS, GR ;
MAWSON, DK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (04) :497-504
[4]   GLAUCOMATOUS CUPPING OF OPTIC DISK BY ULTRASONOGRAPHY [J].
COHEN, JS ;
STONE, RD ;
HETHERINGTON, J ;
BULLOCK, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 82 (01) :24-26
[5]  
Fleiss JL, 2003, STAT METHODS RATES P, P598
[6]  
JUVALA PA, 1987, CHIBRET INT J OPHTHA, V5, P36
[7]   THE CORRELATION BETWEEN CUP-DISK RATIO, NEURORETINAL RIM AREA, AND OPTIC DISK AREA MEASURED BY THE VIDEO-OPHTHALMOGRAPH (RODENSTOCK ANALYZER) AND CLINICAL MEASUREMENT [J].
MIKELBERG, FS ;
DOUGLAS, GR ;
SCHULZER, M ;
AIRAKSINEN, PJ ;
WIJSMAN, K ;
MAWSON, D .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 101 (01) :7-12
[8]   THE CORRELATION BETWEEN OPTIC DISK TOPOGRAPHY MEASURED BY THE VIDEO-OPHTHALMOGRAPH (RODENSTOCK ANALYZER) AND CLINICAL MEASUREMENT [J].
MIKELBERG, FS ;
AIRAKSINEN, PJ ;
DOUGLAS, GR ;
SCHULZER, M ;
WIJSMAN, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (03) :417-419
[9]  
OSSOINIG K C, 1979, International Ophthalmology Clinics, V19, P127, DOI 10.1097/00004397-197901940-00007
[10]  
Skalka H., 1981, NEUROOPHTHALMOLOGY, V1, P261