ADSORPTIVE STRIPPING VOLTAMMETRY OF COBALT AND NICKEL IN FLOW SYSTEMS AT WALL-JET ELECTRODES

被引:56
作者
BRETT, CMA
BRETT, AMCFO
PEREIRA, JLC
机构
[1] Departamento de Quimica, Universidade de Coimbra, Coimbra
关键词
D O I
10.1002/elan.1140030715
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Adsorptive stripping voltammetry of cobalt and nickel in flow systems at wall-jet mercury thin-film electrodes has been investigated and assessed. A HEPES biological buffer with sodium perchlorate electrolyte was employed with excess nioxime, or dimethylglyoxime, ligand, and the accumulated complex on the mercury film surface determined by differential pulse reduction. Concentrations down to 1 nM can be routinely measured. Results at the wall-jet electrode, supported by evidence from LSV and impedance measurements at rotating and stationary electrodes respectively, show the viability of the method.
引用
收藏
页码:683 / 689
页数:7
相关论文
共 32 条
[1]   ASSESSMENT OF DIFFERENTIAL-PULSE ADSORPTION VOLTAMMETRY FOR THE SIMULTANEOUS DETERMINATION OF NICKEL AND COBALT IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :181-194
[2]   THE WALL-JET RING-DISC ELECTRODE .1. THEORY [J].
ALBERY, WJ ;
BRETT, CMA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 148 (02) :201-210
[4]   THE INFLUENCE OF ULTRA-VIOLET IRRADIATION ON THE DETERMINATION OF NICKEL AND COBALT IN NATURAL-WATERS BY ADSORPTION VOLTAMMETRY [J].
BOND, AM ;
LUSCOMBE, DL .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 214 (1-2) :21-29
[5]   ANALYTICAL DETERMINATION OF NICKEL IN THE ENVIRONMENT BY ADSORPTION VOLTAMMETRY USING THE MERCURY FILM ELECTRODE [J].
BRAUN, H ;
METZGER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 318 (05) :321-326
[6]   TRACE-METAL ANALYSIS IN HYDROPONIC SOLUTIONS [J].
BRETT, CMA ;
NETO, MMPM .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1071-1079
[7]   DC ANODIC-STRIPPING VOLTAMMETRY AT MERCURY THIN-FILM ELECTRODES - THE SHAPE AND POSITION OF THE STRIPPING PEAKS AT HYDRODYNAMIC ELECTRODES [J].
BRETT, CMA ;
BRETT, AMCFO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 262 (1-2) :83-95
[8]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244
[9]   DETERMINATION OF NICKEL AND COBALT IN NATURAL-WATERS AND BIOLOGICAL-MATERIAL BY REDUCTIVE CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS IN A FLOW SYSTEM WITHOUT SAMPLE DEOXYGENATION [J].
ESKILSSON, H ;
HARALDSSON, C ;
JAGNER, D .
ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) :79-88
[10]  
GUNASINGHAM H, 1989, ELECTROANALYTICAL CH, V16, P89