IMPROVEMENT IN TRANSFUSION SAFETY USING A NEW BLOOD UNIT AND PATIENT IDENTIFICATION SYSTEM AS PART OF SAFE TRANSFUSION PRACTICE

被引:52
作者
WENZ, B
BURNS, ER
机构
[1] Weiler Hospital, Department of Laboratory Medicine, Albert Einstein College of Medicine, Bronx, New York, 10461
关键词
D O I
10.1046/j.1537-2995.1991.31591263193.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new patient and blood unit identification system designed to confirm the identity of crossmatched blood products and that of the intended recipient was evaluated. Six hundred seventy-two red cell concentrates were transfused to 312 patients. Participating hospital personnel and patients were interviewed regarding the use and benefit of this unique system, which incorporates a "lock-box" approach to the identification process. The product and procedure were accepted unanimously and enthusiastically, and three potential mistransfusions were avoided by use of the system during the limited period of observation. This type of approach to the identification process affords greater security than conventional practices and minimally burdens staff.
引用
收藏
页码:401 / 403
页数:3
相关论文
共 9 条
[1]  
BINDER LS, 1959, SURG GYNECOL OBSTET, V108, P19
[2]   TRANSFUSION-ASSOCIATED FATALITIES - REVIEW OF BUREAU OF BIOLOGICS REPORTS 1976-1978 [J].
HONIG, CL ;
BOVE, JR .
TRANSFUSION, 1980, 20 (06) :653-661
[3]   DECEPTIVELY LOW MORBIDITY FROM FAILURE TO PRACTICE SAFE BLOOD-TRANSFUSION - AN ANALYSIS OF SERIOUS BLOOD-TRANSFUSION ERRORS [J].
MURPHY, WG ;
MCCLELLAND, DBL .
VOX SANGUINIS, 1989, 57 (01) :59-62
[4]  
PINEDA AA, 1978, MAYO CLIN PROC, V53, P378
[5]   REPORTS OF 355 TRANSFUSION-ASSOCIATED DEATHS - 1976 THROUGH 1985 [J].
SAZAMA, K .
TRANSFUSION, 1990, 30 (07) :583-590
[6]   TO ERR IS HUMAN [J].
SHERWOOD, WC .
TRANSFUSION, 1990, 30 (07) :579-580
[7]  
TASWELL HF, 1981, SEMINAR IMMUNE MEDIA, P71
[8]   SPECIAL REPORT - TRANSFUSION RISKS [J].
WALKER, RH .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (03) :374-378
[9]  
YUNIS EJ, 1964, JAMA-J AM MED ASSOC, V189, P907