HARTMANN TEST MODIFICATION FOR MEASURING OPHTHALMIC PROGRESSIVE LENSES

被引:37
作者
CASTELLINI, C
FRANCINI, F
TIRIBILLI, B
机构
[1] Istituto Nazionale di Ottica, Firenze, I-50125
来源
APPLIED OPTICS | 1994年 / 33卷 / 19期
关键词
OPTICAL TESTING; HARTMANN TEST; OPHTHALMIC PROGRESSIVE LENSES;
D O I
10.1364/AO.33.004120
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a modified verion of the Hartmann test in which the pattern of the holes is replaced with a circular scanning laser beam. A position-sensitive detector is used to acquire the coordinates of the deflected beam. Significant data are obtained when the Fourier transform of the detector output signals is considered. Application of this test method to the mapping of optical parameters of ophthalmic progressive addition lenses is presented. Prismatic deviation, spherical power, and astigmatism are measured with appropriate accuracy.
引用
收藏
页码:4120 / 4124
页数:5
相关论文
共 9 条