ACCURATE QUANTIFICATION OF I-131 DISTRIBUTION BY GAMMA-CAMERA IMAGING

被引:60
作者
GREEN, AJ
DEWHURST, SE
BEGENT, RHJ
BAGSHAWE, KD
RIGGS, SJ
机构
[1] Cancer Research Campaign Laboratories, Department of Medical Oncology, Charing Cross and Westminster Medical School, London, W6 8RF, Fulham Palace Road
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1990年 / 16卷 / 4-6期
关键词
Emission tomography; Radiolabelled antibody; Scatter correction; SPET; Targeted therapy;
D O I
10.1007/BF00842793
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of targeted therapy requires that the concentration of the therapeutic agent can be estimated in target and normal tissues. Single photon emission tomography (SPET), with and without scatter correction, and planar imaging using131I have been compared to develop a method for investigation of targeted therapy. Compton scatter was investigated using line spread functions in air and water, these data were used to set a second peak, adjacent to the photopeak, for scatter correction. The system was calibrated with an eliptical phantom containing sources in background activity of various intensities. Scatter corrected reconstructions gave accurate estimates of activity in the sources regardless of background activity. For planar scanning and SPET without scatter correction there was an overestimate of activity in the source of 290% and 40% respectively. The validity of this method was confirmed in patients by comparing activity in the cardiac ventricles measured by SPET with scatter correction with that in a simultaneous blood sample. A coefficient of correlation of 0.955 was achieved with 25 data points. SPET with scatter correction was compared with planar imaging in measuring activity in the liver and spleen of patients receiving 75 mCi131I-antibody to CEA intravenously. Planar imaging gave significantly higher values than SPET for the spleen (t=5.4, P<0.001 by the paired t-test) but no significant difference for the liver. SPET with scatter correction forms a basis for an improved technique of quantifying the targeting efficiency. © 1990 Springer-Verlag.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 11 条
[1]   RADIOIMMUNOLOCALIZATION AND SELECTION FOR SURGERY IN RECURRENT COLORECTAL-CANCER [J].
BEGENT, RHJ ;
KEEP, PA ;
SEARLE, F ;
GREEN, AJ ;
MITCHELL, HDC ;
JONES, BE ;
DENT, J ;
PENDOWER, JEH ;
PARKINS, RA ;
REYNOLDS, KW ;
COOKE, TG ;
MERSH, TA ;
BAGSHAWE, KD .
BRITISH JOURNAL OF SURGERY, 1986, 73 (01) :64-67
[2]  
CARRASQUILLO JA, 1984, CANCER TREAT REP, V68, P317
[4]  
GOLDENBERG DM, 1978, NEW ENGL J MED, V1, P131
[5]   EXTERNAL IMAGING TECHNIQUES FOR QUANTITATION OF DISTRIBUTION OF I-131 F(AB)2 FRAGMENTS OF MONOCLONAL-ANTIBODY IN HUMANS [J].
HAMMOND, ND ;
MOLDOFSKY, PJ ;
BEARDSLEY, MR ;
MULHERN, CB .
MEDICAL PHYSICS, 1984, 11 (06) :778-783
[6]  
JASZCZAK RJ, 1984, J NUCL MED, V25, P893
[7]   REPEATED ANTITUMOUR ANTIBODY THERAPY IN MAN WITH SUPPRESSION OF THE HOST RESPONSE BY CYCLOSPORINE-A [J].
LEDERMANN, JA ;
BEGENT, RHJ ;
BAGSHAWE, KD ;
RIGGS, SJ ;
SEARLE, F ;
GLASER, MG ;
GREEN, AJ ;
DALE, RG .
BRITISH JOURNAL OF CANCER, 1988, 58 (05) :654-657
[8]   DOSIMETRY OF I-131-LABELED ANTI-FERRITIN IN HEPATOMA - A MODEL FOR RADIOIMMUNOGLOBULIN DOSIMETRY [J].
LEICHNER, PK ;
KLEIN, JL ;
GARRISON, JB ;
JENKINS, RE ;
NICKOLOFF, EL ;
ETTINGER, DS ;
ORDER, SE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (03) :323-333
[9]   TUMOR-LOCALIZATION OF RADIOLABELED ANTIBODIES AGAINST CARCINOEMBRYONIC ANTIGEN IN PATIENTS WITH CARCINOMA - A CRITICAL-EVALUATION [J].
MACH, JP ;
CARREL, S ;
FORNI, M ;
RITSCHARD, J ;
DONATH, A ;
ALBERTO, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1980, 303 (01) :5-10
[10]  
SORENSON JA, 1980, PHYSICS NUCLEAR MED