APPLICATION OF RECORDING AND PROCESSING OF ENERGY-FILTERED IMAGE SEQUENCES FOR THE ELEMENTAL MAPPING OF BIOLOGICAL SPECIMENS - IMAGING-SPECTRUM

被引:25
作者
LAVERGNE, JL
FOA, C
BONGRAND, P
SEUX, D
MARTIN, JM
机构
[1] KODAK-PATHE, ANAL LAB, F-71102 CHALON SUR SAONE, FRANCE
[2] HOP ST MARGUERITE, INSERM, U387, IMMUNOL LAB, F-13277 MARSEILLE 9, FRANCE
[3] FAC ODONTOL LYON, DEV & PATHOL TISSU DENTAIRES LAB, CNRS, UPR 412, F-69372 LYON 8, FRANCE
关键词
ELECTRON ENERGY-LOSS SPECTROSCOPY (EELS); ENERGY-FILTERED TRANSMISSION ELECTRON MICROSCOPY (EFTEM); CALCIUM LOCALIZATION; CELL ADHESION; IMAGE ANALYSIS; IMAGING-SPECTRUM;
D O I
10.1111/j.1365-2818.1994.tb03467.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Computerized energy-filtered transmission electron microscope (EFTEM) permits the recording and the processing of energy-filtered images, allowing a part of an electron energy-loss spectrum for each picture element to be obtained. This method, called 'Imaging-Spectrum', uses a Zeiss CEM902 coupled to several image analysis systems. The actual configuration records sequences of 48 images, 256 x 256 pixels, in steps of the energy loss, Delta E. Processing these sequences results in part of a core-loss EELS-spectrum for each pixel. This approach produces elemental maps with a short processing time. We have implemented three kinds of background calculation for the image subtraction. The influence of the irradiation dose and of the energy selecting slit width on the quality of the spectra is investigated. The method is applied to the analysis of some biological specimens (pericellular coat behaviour during adhesion between macrophages and red blood cells and location of calcite microcrystals in dental pulp cells). The Imaging-Spectrum method appears to be suitable for the analysis of large areas.
引用
收藏
页码:195 / 206
页数:12
相关论文
共 21 条
[1]   PARALLEL EELS ELEMENTAL MAPPING IN SCANNING-TRANSMISSION ELECTRON-MICROSCOPY - USE OF THE DIFFERENCE-METHODS [J].
BALOSSIER, G ;
THOMAS, X ;
MICHEL, J ;
WAGNER, D ;
BONHOMME, P ;
PUCHELLE, E ;
PLOTON, D ;
BONHOMME, A ;
PINON, JM .
MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1991, 2 (05) :531-546
[2]  
BERGER A, 1993, OPTIK, V92, P175
[3]   ELEMENTAL MAPPING USING AN IMAGING ENERGY FILTER - IMAGE-FORMATION AND RESOLUTION LIMITS [J].
BERGER, A ;
KOHL, H .
MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1992, 3 (2-3) :159-174
[4]  
BONGRAND P, 1988, PHYSICL BASIS CELL C
[5]  
BONNET N, 1988, SCANNING MICROSCOPY, P351
[6]  
Colliex C., 1984, ADV OPTICAL ELECTRON, V9, P65
[7]   INELASTIC-SCATTERING OF 80 KEV ELECTRONS IN AMORPHOUS CARBON [J].
EGERTON, RF .
PHILOSOPHICAL MAGAZINE, 1975, 31 (01) :199-215
[8]  
FOA C, 1993, ATELIER INSERM, V56
[9]   ELECTRON ENERGY-LOSS SPECTRUM-IMAGING [J].
HUNT, JA ;
WILLIAMS, DB .
ULTRAMICROSCOPY, 1991, 38 (01) :47-73
[10]   INTEGRINS - VERSATILITY, MODULATION, AND SIGNALING IN CELL-ADHESION [J].
HYNES, RO .
CELL, 1992, 69 (01) :11-25