ROUTINE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY UNCONJUGATED CORTISOL USING SOLID-PHASE EXTRACTION AND ULTRAVIOLET DETECTION

被引:8
作者
DOLEZALOVA, M [1 ]
机构
[1] UNIV HOSP PRAGUE,PRAGUE,CZECH REPUBLIC
关键词
FREE CORTISOL; UNCONJUGATED CORTISOL; URINE; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC); SOLID-PHASE EXTRACTION;
D O I
10.1016/0009-8981(94)90197-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
An HPLC method with solid-phase extraction for the specific determination of urinary free cortisol is described. A 3-ml urine sample is cleaned up on a disposable cartridge C 18, After successive washing with 0.025 mol/l berate buffer (pH 7.5) and a mixture of acetone and water, retained cortisol and 6 alpha-methylprednisolone (internal standard) are eluted with ethyl acetate. The recovery of cortisol is 92.9 +/- 4.4%. The reversed-phase chromatographic procedure uses an octadecyl-bonded column with a mobile phase composed of methanol, tetrahydrofuran and water with UV detection at 245 nm, The calibration curve is linear up to a cortisol concentration of 356 nmo/l. Coefficients of variation show good reproducibility of the assay, The detection limit is 9 nmo/l (16 pmol injected). The normal range of urinary free cortisol excretion was found to be 17-132 nmol/24 h. This simple and convenient method is suitable for routine use.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 15 条
[1]  
COPE CL, 1959, BRIT MED J, V11, P1117
[2]  
HUANG CM, 1989, CLIN CHEM, V35, P125
[3]   DETERMINATION OF PLASMA AND URINARY CORTISOL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING FLUORESCENCE DERIVATIZATION WITH DANSYL HYDRAZINE [J].
KAWASAKI, T ;
MAEDA, M ;
TSUJI, A .
JOURNAL OF CHROMATOGRAPHY, 1979, 163 (02) :143-150
[4]  
LANTTO O, 1982, CLIN CHEM, V28, P1129
[5]  
MACHACEK D, 1986, CLIN CHEM, V32, P1163
[6]   LACK OF SPECIFICITY OF CORTISOL DETERMINATIONS IN HUMAN-URINE [J].
MURPHY, BEP ;
OKOUNEFF, LM ;
KLEIN, GP ;
NGO, SC .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1981, 53 (01) :91-99
[7]   CHROMATOGRAPHY AS A REFERENCE TECHNIQUE FOR THE DETERMINATION OF CLINICALLY IMPORTANT STEROIDS [J].
ROBARDS, K ;
TOWERS, P .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (01) :1-19
[8]   SPECIFIC AND PRACTICABLE ASSESSMENT OF URINARY FREE CORTISOL BY COMBINATION OF AUTOMATIC HIGH-PRESSURE LIQUID-CHROMATOGRAPHY AND RADIOIMMUNOASSAY [J].
SCHONESHOFER, M ;
FENNER, A ;
ALTINOK, G ;
DULCE, HJ .
CLINICA CHIMICA ACTA, 1980, 106 (01) :63-73
[9]   INTERFERENCES IN THE RADIOIMMUNOLOGICAL DETERMINATION OF URINARY FREE CORTISOL [J].
SCHONESHOFER, M ;
FENNER, A ;
DULCE, HJ .
CLINICA CHIMICA ACTA, 1980, 101 (01) :125-134
[10]  