A 6 df measurement system was used to investigate the initial relative bone-implant motion of two types of cementless total hip replacement femoral components-a straight stem and a curved stem. Five pairs of fresh frozen femurs from human cadavers were tested with loads applied to the femoral head at angles characteristic of level walking, stair-climbing, and rising from a chair. The most important findings were that (a) the resultant proximal translations were twice as high with the straight stem as with the curved stem at load angles encountered in stair-climbing and rising from a chair, (b) both stem types had more motion at load angles encountered in stair-climbing and rising from a chair than in level walking, with the increases ranging from 3 to 14-fold, (c) there was as much as 66-fold more motion distally than proximally, and (d) the amount of interface motion varied by 5-fold between the medial and lateral surfaces of the distal part of the implant because of the combined effects of translation and rotation. The amount of initial bone-implant motion of the femoral component was found to be particularly sensitive to off-axis loading; this suggests that stair-climbing and rising from a chair should be avoided in the early postoperative period when a cementless porous-coated femoral stem has been used.
引用
收藏
页码:758 / 769
页数:12
相关论文
共 34 条
[1]  
ANDERSON GI, 1990, T ORTHOP RES SOC, V15, P463
[2]   A STUDY OF LOWER-LIMB MECHANICS DURING STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
ANDERSSON, GBJ ;
FERMIER, RW ;
STERN, D ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05) :749-757
[3]  
BECHTOLD JE, 1989, T ORTHOP RES SOC, V14, P380
[4]  
BERGMANN G, 1990, 7TH P M EUR SOC BIOM, pB40
[5]   THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[6]  
CAVIGLIA HA, 1989, T ORTHOP RES SOC, V14, P580
[7]  
CHARNLEY J, 1965, J Bone Joint Surg Br, V47, P354
[8]  
CHARNLEY J, 1965, J Bone Joint Surg Br, V47, P56
[9]  
COLLIER JP, 1992, CLIN ORTHOP RELAT R, V274, P97
[10]  
GILBERT JL, 1992, J BIOMECH, V24, P329