摘要
Lipophilic alpha, beta and gamma cyclodextrins (CDs) have been systematically analysed in order to establish their selective binding to onium ions. They have been identified as excellent ionophores for a range of ions of vital importance in clinical, pharmaceutical and forensic analysis. From the results obtained we found the following. A peroctylated cyclodextrin provides a size-selective cavity for the binding and detection of onium ions. Potentiometric alpha, beta and gamma cyclodextrin-based electrodes selectively sense NH4+, NMe(4)(+) and NEt(4)(+) ions respectively. These experiments were performed in order to enable us to understand the nature of analyte recognition by the lipophilic cyclodextrins. Peroctylated alpha CD is a suitable ionophore for dopamine hydrochloride, - log [C] = 5.4, - log K = 2.0 (in serum level of Na+, K+, Ca2+) whereas peroctylated and 2,6 didodecyl beta CD sense acetylcholine chloride, - log[C] = 5.0, - log K = 4.2 (in serum level of Na+, K+, Ca2+) and creatinine hydrochloride, - log K = 2.7 (in serum level of Na+, K+, Ca2+), respectively. The 2,6 didodecyl beta CD responds to more bulky aryl ammonium ions such as the anaesthetics procaine, prilocaine and lignocaine hydrochlorides, - log K = 4.2 (in serum level of Na+, K+, Ca2+). Partially octylated alpha CD has been identified as an enantioselective sensor for ephedrine hydrochloride, - log K = 4.5 (in serum level of Na+, K+, Ca2+), - log K-+/-(pot) = 2.6, and related compounds such as amphetamine hydrochloride. The 2,6 didodecyl beta CD is enantioselective for propranalol hydrochloride, - log K = 4.2 (in serum level of Na+, K+, Ca2+), - log K-+/-(pot) = 2.7. Complexation has also been studied by electrospray mass spectrometry (ESMS).
引用
收藏
页码:409 / 419
页数:11
相关论文
共 16 条
[1]   CHIRAL SENSORS BASED ON LIPOPHILIC CYCLODEXTRINS - INTERROGATION OF ENANTIOSELECTIVITY BY COMBINED NMR, STRUCTURAL CORRELATION AND ELECTRODE RESPONSE STUDIES [J].
BATES, PS ;
KATAKY, R ;
PARKER, D .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1994, (04) :669-675
[2]   CHARACTERIZATION OF THE COMPLEXATION BEHAVIOR OF LIPOPHILIC CYCLODEXTRINS BY ELECTROSPRAY MASS-SPECTROMETRY [J].
BATES, PS ;
PARKER, D ;
GREEN, BN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1993, (08) :693-696
[3]   SYNTHESIS AND SPECTROSCOPIC CHARACTERIZATION OF LIPOPHILIC OCTYLATED ALPHA-CYCLODEXTRIN, BETA-CYCLODEXTRIN AND GAMMA-CYCLODEXTRIN DERIVATIVES [J].
BATES, PS ;
PARKER, D ;
PATTI, AF .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1994, (04) :657-668
[4]  
BUSSMANN W, 1981, HELV CHIM ACTA, V64, P557
[5]  
GOLDENBERG RN, 1985, NBS1206 TECHN NOT
[6]   COMPARATIVE PERFORMANCE OF 14-CROWN-4 DERIVATIVES AS LITHIUM-SELECTIVE ELECTRODES [J].
KATAKY, R ;
NICHOLSON, PE ;
PARKER, D ;
COVINGTON, AK .
ANALYST, 1991, 116 (02) :135-140
[7]   FUNCTIONALIZED ALPHA-CYCLODEXTRINS AS POTENTIOMETRIC CHIRAL SENSORS [J].
KATAKY, R ;
BATES, PS ;
PARKER, D .
ANALYST, 1992, 117 (08) :1313-1317
[8]  
KATAKY R, 1994, ANALYST, V119, P181
[9]   SURFACTANT INCLUSIONS BY MODIFIED BETA-CYCLODEXTRINS [J].
LAVANDIER, CD ;
PELLETIER, MP ;
REINSBOROUGH, VC .
AUSTRALIAN JOURNAL OF CHEMISTRY, 1991, 44 (03) :457-461
[10]  
LI S, 1992, CHEM REV, P1457