SEC-VISCOMETER DETECTOR SYSTEMS .2. RESOLUTION CORRECTION AND DETERMINATION OF INTERDETECTOR VOLUME

被引:30
作者
CHEUNG, P
LEW, R
BALKE, ST
MOUREY, TH
机构
[1] UNIV TORONTO,DEPT CHEM ENGN & APPL CHEM,TORONTO M5S 1A4,ONTARIO,CANADA
[2] EASTMAN KODAK CO,RES LABS,DIV ANALYT TECHNOL,ROCHESTER,NY 14650
关键词
D O I
10.1002/app.1993.070470917
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The closely related topics of resolution correction and the determination of interdetector volume were examined. In determining the interdetector volume (delta) by searching to superimpose two types of intrinsic viscosity calibation curve (one-from narrow standards and one from a broad standard), the underlying equation based upon symmetrical axial dispersion theory was derived. This equation combined with experimental results showed that the local intrinsic viscosity value is very similarly affected by interdetector volume and by band spreading. The result supported the idea of using an effective delta to effect an axial dispersion correction to local intrinsic viscosity data. However, it also increased the difficulty of finding both delta and standard deviation (sigma) simultaneously by numerical search. Furthermore, attempts to apply the method to the chromatograms of narrow standards showed inadequate superposition. Following calculation of skewing factors, the superposition problems were attributed to skewing of the chromatograms of the monodisperse polymer standards used.
引用
收藏
页码:1701 / 1706
页数:6
相关论文
共 15 条
[1]  
Balke S. T., 1991, J APPL POLYM SCI APP, V48, P259
[2]  
Balke S.T., 1984, QUANTITATIVE COLUMN
[3]   POLYMER REACTORS AND MOLECULAR WEIGHT DISTRIBUTION .8. A METHOD OF INTERPRETING SKEWED GPC CHROMATOGRAMS [J].
BALKE, ST ;
HAMIELEC, AE .
JOURNAL OF APPLIED POLYMER SCIENCE, 1969, 13 (07) :1381-&
[4]   QUANTITATIVE SIZE EXCLUSION CHROMATOGRAPHY - ASSESSING NEW DEVELOPMENTS [J].
BALKE, ST ;
CHEUNG, P ;
LEW, R ;
MOUREY, TH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (15) :2929-2955
[5]  
BALKE ST, 1991, IN PRESS ACS S SERIE
[6]  
BALKE ST, 1980, ACS SYM SER, V138, P149
[7]   CALIBRATION OF SEPARATION AND INSTRUMENTAL PEAK BROADENING IN SEC COUPLED WITH LIGHT-SCATTERING OF SIMPLE POLYMERS [J].
BILLIANI, J ;
AMTMANN, I ;
MAYR, T ;
LEDERER, K .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (15) :2973-2986
[8]   DATA INTERPRETATION FOR COUPLED MOLECULAR-WEIGHT SENSITIVE DETECTORS IN SEC - INTERDETECTOR TRANSPORT TIME [J].
CHEUNG, P ;
BALKE, ST ;
MOUREY, TH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (01) :39-69
[9]   INSTRUMENTAL BROADENING CORRECTION IN SIZE EXCLUSION CHROMATOGRAPHY - COMPARISON OF SEVERAL DECONVOLUTION TECHNIQUES [J].
GUGLIOTTA, LM ;
VEGA, JR ;
MEIRA, GR .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (09) :1671-1708