THE RESULTS OF COMPUTER-ASSISTED AMBULATORY 16-CHANNEL EEG

被引:37
作者
MORRIS, GL
GALEZOWSKA, J
LEROY, R
NORTH, R
机构
[1] ZABLOCKI VA HOSP,MILWAUKEE,WI 53226
[2] MED CITY HOSP,DALLAS,TX
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1994年 / 91卷 / 03期
关键词
AMBULATORY EEG; COMPUTER-ASSISTED EEG MONITORING; 16-CHANNEL EEG;
D O I
10.1016/0013-4694(94)90073-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to examine the results of 16-channel computer-assisted outpatient long-term EEG monitoring (CO-LTM) and to compare those results to previously published reports using 4- and 8-channel ambulatory cassette-based continuous recordings. Patients were referred to a community-based outpatient EEG service for further diagnostic evaluation using this 16-channel bipolar recording system. 344 patients were recorded for an average of 1.4 days. EEG was reviewed for the presence of patient identified events, computer identified interictal and ictal abnormalities, and periodic time samples. A push-button recording that signified a clinical event was obtained in 166 patients (48.3%); 41 (11.9%) of these recordings included a seizure and 125 (36.3%) showed no EEG changes during the habitual event. An EEG abnormality was identified by the computer in an additional 90 recordings (26.2%), for an overall clinical usefulness of 74.4%. Among the 191 patients referred with previously normal routine EEGs, a total of 129 (67.5%) of these recordings were useful. 48 (25.1%) of these tracings were abnormal and an additional 81 push-button events (42.4%) showing no changes from background EEG were recorded. In conclusion, computer-assisted outpatient EEG monitoring provides good success rates for clinically useful information.
引用
收藏
页码:229 / 231
页数:3
相关论文
共 12 条
[1]   INCIDENCE OF SEIZURES WITH PHENYTOIN TOXICITY [J].
BRIDGERS, SL ;
EBERSOLE, JS .
NEUROLOGY, 1985, 35 (12) :1767-1768
[2]   THE CLINICAL UTILITY OF AMBULATORY CASSETTE EEG [J].
BRIDGERS, SL ;
EBERSOLE, JS .
NEUROLOGY, 1985, 35 (02) :166-173
[3]   EVALUATION OF AMBULATORY CASSETTE EEG MONITORING .3. DIAGNOSTIC-ACCURACY COMPARED TO INTENSIVE INPATIENT EEG MONITORING [J].
EBERSOLE, JS ;
LEROY, RF .
NEUROLOGY, 1983, 33 (07) :853-860
[4]   AN EVALUATION OF AMBULATORY, CASSETTE EEG MONITORING .2. DETECTION OF INTERICTAL ABNORMALITIES [J].
EBERSOLE, JS ;
LEROY, RF .
NEUROLOGY, 1983, 33 (01) :8-18
[5]   DIRECT COMPARISON OF 3-CHANNEL AND 8-CHANNEL AMBULATORY CASSETTE EEG WITH INTENSIVE INPATIENT MONITORING [J].
EBERSOLE, JS ;
BRIDGERS, SL .
NEUROLOGY, 1985, 35 (06) :846-854
[6]   AMBULATORY CASSETTE EEG [J].
EBERSOLE, JS .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1985, 2 (04) :397-418
[7]  
EBERSOLE JS, 1989, AMBULATORY EEG MONIT, P111
[8]   AUTOMATIC RECOGNITION AND QUANTIFICATION OF INTERICTAL EPILEPTIC ACTIVITY IN HUMAN SCALP EEG [J].
GOTMAN, J ;
GLOOR, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1976, 41 (05) :513-529
[9]   AUTOMATIC RECOGNITION OF EPILEPTIC SEIZURES IN THE EEG [J].
GOTMAN, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1982, 54 (05) :530-540
[10]   PRACTICAL USE OF COMPUTER-ASSISTED EEG INTERPRETATION IN EPILEPSY [J].
GOTMAN, J .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1985, 2 (03) :251-265