FLEXIBLE ELECTROGONIOMETERS - KINESIOLOGICAL ADVANTAGES WITH RESPECT TO POTENTIOMETRIC GONIOMETERS

被引:24
作者
TESIO, L
MONZANI, M
GATTI, R
FRANCHIGNONI, F
机构
[1] Department of Research, Functional Assessment and Quality Assurance in Neuromotor Rehabilitation, Fondazione Clinica del Lavoro
[2] Servizio di Fisiatria, Clinica Ortopedica, Istituto Scientifico H San Raffaele, Milano
关键词
ELECTROGONIOMETER; KINESIOLOGY; KNEE; ANKLE;
D O I
10.1016/0268-0033(95)00017-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Unlike conventional potentiometric goniometers, flexible electrogoniometers do not suffer from any alignment problems with respect to the joint axis. We hypothesized that flexible goniometers provide more valid measurements in that they avoid some biomechanical pitfalls. With both devices simultaneously we measured the movements of dorsal flexion of the ankle and flexion of the knee in three healthy subjects. In the various subjects, this comparison showed that the flexible goniometers signalled ankle excursion greater by 19-40% with the foot remaining in neutral position or being simultaneously pronated, and lower by 10-21% with the foot being simultaneously supinated. At the knee the flexible goniometers signalled a flexion greater by 24-32%, with respect to potentiometric goniometers. Biomechanical considerations support the validity of records taken with flexible goniometers, potentiometric measures being biased by (a) multijoint, multiplane motions underlying foot dorsal flexion, and (b) multiaxis motion underlying knee flexion Relevance In measurements of angles between adjacent body segments, flexible goniometers should be preferred to potentiometric goniometers despite their higher cost. Flexible goniometers not only are more practical: more importantly, they provide a valid measure of relative orientations in one plane, regardless of the number and different concurrent motions of the underlying joints.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 7 条
[1]  
Nicol, A new flexible electrogoniometer with widespread applications, Biomechanics X-B, pp. 1029-1033, (1987)
[2]  
Nicol, A triaxial flexible electrogoniometer, Biomechanics XI-B, pp. 964-967, (1988)
[3]  
Rowe, Nicol, Kelly, Flexible goniometer computer system for the assessment of hip function, Clin Biomech, 4, pp. 68-72, (1989)
[4]  
Ball, Johnson, Reliability of hindfoot goniometry when using a flexible electrogoniometer, Clin Biomech, 8, pp. 13-19, (1993)
[5]  
Finley, Karpovich, Electrogoniometric analysis of normal and pathological gaits, Res Q, 35, pp. 379-384, (1964)
[6]  
Root, Orien, Weed, Hughes, Biomechanical Examination of the Foot, 1, (1978)
[7]  
Kapandji, Physiologie Articulaire, (1974)