COMPARATIVE ACCURACY OF DOPPLER ECHOCARDIOGRAPHIC METHODS FOR CLINICAL STROKE VOLUME DETERMINATION

被引:226
作者
DUBIN, J [1 ]
WALLERSON, DC [1 ]
CODY, RJ [1 ]
DEVEREUX, RB [1 ]
机构
[1] CORNELL UNIV,MED CTR,NEW YORK HOSP,DIV CARDIOL,BOX 222,525 E 68TH ST,NEW YORK,NY 10021
关键词
D O I
10.1016/0002-8703(90)90168-W
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Numerous Doppler echocardiographic methods to measure stroke volume have been proposed in experimental or clinical studies, but their relative accuracy in patients compared with an invasive reference standard remains uncertain. Accordingly, we compared Doppler with thermodilution stroke volume measurement in 18 hospitalized patients, 16 with an acute manifestation of coronary artery disease and two with chronic cardiomyopathies. Doppler time-velocity integrals were measured by darkest line (modal velocity) and the leading edge (maximal velocity) techniques at the aortic annular plane, the mitral orifice, and the mitral annular plane. Two-dimensional echocardiography was used to measure cross-sectional areas (M-mode-corrected at the mitral orifice). The combination of aortic annular cross-sectional area and the leading edge technique of measuring the time-velocity integral of blood flow at this site provided the most accurate measure of stroke volume (r = 0.87, p < 0.0001, standard error of estimate = 11 cm3; mean difference from thermodilution = 2.8 ml ± 8.9 ml, p = NS). It also resulted in the most accurate measurement of cardiac output (r = 0.88, p < 0.0003; mean difference from thermodilution = 0.11 L/min ± 0.69 L/min, p = NS). Other methods yielded values that correlated less closely and deviated systematically from thermodilution measurements. We therefore conclude that of the six common methods evaluated, the aortic annular leading edge method measures stroke volume with the best accuracy and is most suitable for clinical application. © 1990.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 17 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] MEASUREMENT OF LEFT-VENTRICULAR STROKE VOLUME USING CONTINUOUS WAVE DOPPLER ECHOCARDIOGRAPHY OF THE ASCENDING AORTA AND M-MODE ECHOCARDIOGRAPHY OF THE AORTIC-VALVE
    BOUCHARD, A
    BLUMLEIN, S
    SCHILLER, NB
    SCHLITT, S
    BYRD, BF
    PORTS, T
    CHATTERJEE, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) : 75 - 83
  • [3] DETERMINATION OF CARDIAC-OUTPUT BY TRANS-CUTANEOUS CONTINUOUS-WAVE ULTRASONIC DOPPLER COMPUTER
    CHANDRARATNA, PA
    NANNA, M
    MCKAY, C
    NIMALASURIYA, A
    SWINNEY, R
    ELKAYAM, U
    RAHIMTOOLA, SH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) : 234 - 237
  • [4] INFLUENCE OF SAMPLING SITE AND FLOW AREA ON CARDIAC-OUTPUT MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY
    DITTMANN, H
    VOELKER, W
    KARSCH, KR
    SEIPEL, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) : 818 - 823
  • [5] THE MITRAL-VALVE ORIFICE METHOD FOR NON-INVASIVE TWO-DIMENSIONAL ECHO DOPPLER DETERMINATIONS OF CARDIAC-OUTPUT
    FISHER, DC
    SAHN, DJ
    FRIEDMAN, MJ
    LARSON, D
    VALDESCRUZ, LM
    HOROWITZ, S
    GOLDBERG, SJ
    ALLEN, HD
    [J]. CIRCULATION, 1983, 67 (04) : 872 - 877
  • [6] THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS
    FISHER, DC
    SAHN, DJ
    FRIEDMAN, MJ
    LARSON, D
    VALDESCRUZ, LM
    HOROWITZ, S
    GOLDBERG, SJ
    ALLEN, HD
    [J]. CIRCULATION, 1983, 67 (02) : 370 - 376
  • [7] GILLAM LD, 1985, CIRCULATION, V72, P99
  • [8] EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS
    GOLDBERG, SJ
    SAHN, DJ
    ALLEN, HD
    VALDESCRUZ, LM
    HOENECKE, H
    CARNAHAN, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) : 1394 - 1400
  • [9] Hatle L, 1985, DOPPLER ULTRASOUND C, P93
  • [10] NON-INVASIVE DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN MAN - CLINICAL VALIDATION
    HUNTSMAN, LL
    STEWART, DK
    BARNES, SR
    FRANKLIN, SB
    COLOCOUSIS, JS
    HESSEL, EA
    [J]. CIRCULATION, 1983, 67 (03) : 593 - 602