COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES

被引:189
作者
MELKI, PS
MULKERN, RV
PANYCH, LP
JOLESZ, FA
机构
[1] Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, 02115
[2] Department of Radiology, Children's Hospital, Boston
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1991年 / 1卷 / 03期
关键词
HEAD; MR STUDIES; 10.1214; PHYSICS; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1002/jmri.1880010310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The FAISE (fast-acquisition interleaved spin-echo) technique consists of a hybrid rapid-acquisition relaxation-enhanced (RARE) sequence combined with a specific phase-encode reordering method. Implemented on a 1.5-T unit, this multisection. high-resolution technique permits convenient contrast manipulation similar to that of spin-echo imaging, with selection of a pseudo-echo-time parameter and a TR interval. With a TR of 2 seconds, eight 256 x 256 images are obtained in 34 seconds with either T2 or protondensity weighting. A direct comparison between FAISE and spin echo for obtaining T2-weighted head images in healthy subjects indicates that FAISE and spin-echo images are qualitatively and quantitatively similar. Image artifacts are more pronounced on "proton-density" FAISE images than on the T2-weighted FAISE images. Tl contrast can be obtained with inversion recovery and short TR FAISE images. Preliminary temperature measurements in saline phantoms do not indicate excessive temperature increases with extended FAISE acquisitions. However, extensive studies of radio-frequency power deposition effects should be performed if the FAISE technique is to be fully exploited.
引用
收藏
页码:319 / 326
页数:8
相关论文
共 16 条
  • [1] Hennig J, Naureth A, Friedburg H, RARE imaging: a fast imaging method for clinical MR, Magn Reson Med, 3, pp. 823-833, (1986)
  • [2] Hennig J, Friedburg H, Clinical applications and methodological developments of the RARE technique, Magn Reson Imaging, 6, pp. 391-395, (1988)
  • [3] Twieg DB, The k‐space trajectory formulation of the NMR imaging process with applications in analysis and imaging methods, Med Phys, 10, pp. 610-621, (1983)
  • [4] Mulkern RV, Wong STS, Winalski C, Jolesz FA, Contrast manipulation and artifact assessment of 2D and 3D RARE sequences, Magn Reson Imaging, 8, pp. 557-566, (1990)
  • [5] Santyr GE, Henkelman RM, Bronskill MJ, Variation in measured transverse relaxation in tissue resulting from spin locking with the CPMG sequence, J Magn Reson, 79, pp. 28-44, (1988)
  • [6] Allerhand A, Analysis of Carr‐Purcell spin‐echo NMR experiments on multiple‐spin systems. I. The effect of homonuclear coupling, The Journal of Chemical Physics, 44, pp. 1-9, (1966)
  • [7] Carver JP, Richards RE, A general two‐site solution for the chemical exchange produced dependence of T2 upon the Carr‐Purcell pulse separation, J Magn Reson, 6, pp. 89-105, (1972)
  • [8] Gutowsky HS, Vold RL, Wells EJ, Theory of chemical exchange effects in magnetic resonance, J Chem Phys, 43, pp. 4107-4125, (1965)
  • [9] Bendel P, Spin‐echo attenuation by diffusion in non‐uniform field gradients, J Magn Reson, 86, pp. 509-515, (1990)
  • [10] Rozenman Y, Zou X, Kantor HL, Signal loss induced by superparamagnetic iron oxide particles in NMR spin‐echo images: the role of diffusion, Magn Reson Med, 14, pp. 31-39, (1990)