EFFECT OF NEEDLE GAUGE, LEVEL OF ANTICOAGULATION, AND TARGET ORGAN ON BLEEDING ASSOCIATED WITH ASPIRATION BIOPSY - WORK IN PROGRESS

被引:74
作者
GAZELLE, GS [1 ]
HAAGA, JR [1 ]
ROWLAND, DY [1 ]
机构
[1] CASE WESTERN RESERVE UNIV HOSP,DEPT RADIOL,CLEVELAND,OH 44106
关键词
BIOPSIES; COMPLICATIONS; KIDNEY; BIOPSY; LIVER;
D O I
10.1148/radiology.183.2.1561359
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Percutaneous fine-needle aspiration biopsy has gained wide acceptance due to its accuracy, ease of performance, and safety. This study was performed to evaluate the effect of needle size, coagulation impairment, or biopsy of different organs on risk of bleeding during the procedure. Multiple biopsy procedures were performed on the livers and kidneys of anesthetized pigs with 14-22-gauge Chiba-type needles. The procedures were performed under direct vision at laparotomy, and blood loss was measured. While larger needles generally produced more bleeding, the differences were statistically significant only when comparing 14-with 16-gauge needles and 16-gauge needles with the group of 18-, 20-, and 22-gauge needles in the liver. In the kidney, no significant difference was noted between 18-, 20-, and 22-gauge needles. Anticoagulation did not produce significantly greater blood loss but did allow separation of the group of 18- and 20-gauge needles from 22-gauge needles in the kidney. Renal biopsy resulted in greater overall blood loss than did liver biopsy.
引用
收藏
页码:509 / 513
页数:5
相关论文
共 26 条
[1]   CT DIRECTED HEPATIC BIOPSIES - INCREASED DIAGNOSTIC-ACCURACY WITH LOW PATIENT RISK [J].
ALSPAUGH, JP ;
BERNARDINO, ME ;
SEWELL, CW ;
SONES, PJ ;
BERKMAN, WA ;
PRICE, RB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (06) :1012-1017
[2]   BIOPSY NEEDLE CHARACTERISTICS ASSESSED IN THE LABORATORY [J].
ANDRIOLE, JG ;
HAAGA, JR ;
ADAMS, RB ;
NUNEZ, C .
RADIOLOGY, 1983, 148 (03) :659-662
[3]  
BRET PM, 1986, J CAN ASSOC RADIOL, V37, P5
[4]   FATAL NECROTIZING PANCREATITIS FOLLOWING FINE-NEEDLE ASPIRATION BIOPSY OF THE PANCREAS [J].
EVANS, WK ;
HO, CS ;
MCLOUGHLIN, MJ ;
TAO, LC .
RADIOLOGY, 1981, 141 (01) :61-62
[5]  
FERRUCCI JT, 1979, RADIOLOGY, V130, P345, DOI 10.1148/130.2.345
[6]   HEMOSTATIC PROTEIN-POLYMER SHEATH - NEW METHOD TO ENHANCE HEMOSTASIS AT PERCUTANEOUS BIOPSY [J].
GAZELLE, GS ;
HAAGA, JR ;
NEUHAUSER, D .
RADIOLOGY, 1990, 175 (03) :671-674
[7]   CLINICAL COMPARISON OF SMALL-CALIBER AND LARGE-CALIBER CUTTING NEEDLES FOR BIOPSY [J].
HAAGA, JR ;
LIPUMA, JP ;
BRYAN, PJ ;
BALSARA, VJ ;
COHEN, AM .
RADIOLOGY, 1983, 146 (03) :665-667
[8]  
HARTLEY HO, 1958, BIOMETR TABLES ST, P173
[9]  
JOHNSON NL, 1964, ENG PHYSICAL SCI, V2, P54
[10]   HISTOLOGY FROM ASPIRATION BIOPSY - TURNER NEEDLE EXPERIENCE [J].
LIEBERMAN, RP ;
HAFEZ, GR ;
CRUMMY, AB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (03) :561-564