IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ASSAY FOR ATENOLOL IN PLASMA AND URINE USING FLUORESCENCE DETECTION

被引:16
作者
MORRIS, RG
SACCOIA, NC
SALLUSTIO, BC
ZACEST, R
机构
[1] Department of Clinical Pharmacology, The Queen Elizabeth Hospital, SA
关键词
HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; ATENOLOL ANALYSIS; PHARMACOKINETICS; ENANTIOMERS;
D O I
10.1097/00007691-199107000-00011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
An improved assay for racemic atenolol (AT) concentrations in human plasma and urine is described using a high-performance liquid chromatographic method with fluorescence detection. The method has a sensitivity limit of 0.5-mu-g/L in plasma with acceptable within- and between-run reproducibilities, and demonstrated linearity at concentrations up to 2,000-mu-g/L. A pilot clinical evaluation of the assay was undertaken on 56 trough plasma specimens from 36 outpatients on established AT therapy. Atenolol concentrations in these patients showed large variations at all prescribed doses, including undetectable levels in four patients (revealing unsuspected noncompliance). Because of its sensitivity and applicability to urinary analysis, the method can be used for pharmacokinetic studies and, under certain circumstances, may be valuable in clinical therapeutic drug monitoring.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 12 条
[1]  
BOLLI P, 1990, HYPERTENSION PATHOPH, V2, P2181
[2]   STUDIES ON PHARMACOKINETICS AND PHARMACODYNAMICS OF ATENOLOL IN MAN [J].
FITZ GERALD, JD ;
RUFFIN, R ;
SMEDSTAD, KG ;
ROBERTS, R ;
MCAINSH, J .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1978, 13 (02) :81-89
[3]  
FRISHMAN WH, 1990, CARDIOVASCULAR DRUG, P394
[4]   OBESITY AND BETA-BLOCKERS - INFLUENCE OF BODY-FAT ON THEIR KINETICS AND CARDIOVASCULAR EFFECTS [J].
GALLETTI, F ;
FASANO, ML ;
FERRARA, LA ;
GROPPI, A ;
MONTAGNA, M ;
MANCINI, M .
JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 29 (03) :212-216
[5]   ATENOLOL, NADOLOL, AND PINDOLOL IN ANGINA-PECTORIS ON EFFORT - EFFECT OF PHARMACOKINETICS [J].
KOSTIS, JB ;
LACY, CR ;
KRIEGER, SD ;
COSGROVE, NM .
AMERICAN HEART JOURNAL, 1984, 108 (04) :1131-1136
[6]   BETA-BLOCKING-AGENTS - DETERMINATION OF BIOLOGICAL LEVELS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LEFEBVRE, MA ;
GIRAULT, J ;
FOURTILLAN, JB .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1981, 4 (03) :483-500
[7]   PHARMACOKINETICS OF ATENOLOL ENANTIOMERS IN HUMANS AND RATS [J].
MEHVAR, R ;
GROSS, ME ;
KREAMER, RN .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (10) :881-885
[9]   DETERMINATION OF ATENOLOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH APPLICATION TO SINGLE-DOSE PHARMACOKINETICS [J].
MILLER, LG ;
GREENBLATT, DJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :201-204
[10]  
PEAT MA, 1989, DETERMINATION BETA B, P5