VARIATIONS IN RESULTS OF SIMULTANEOUS AMBULATORY ESOPHAGEAL PH MONITORING

被引:15
作者
HAMPTON, FJ [1 ]
MACFADYEN, UM [1 ]
MAYBERRY, JF [1 ]
机构
[1] UNIV LEICESTER,LEICESTER GEN HOSP,DEPT MED,DEPT CHILD HLTH,LEICESTER LE1 7RH,ENGLAND
关键词
GASTROESOPHAGEAL REFLUX; ESOPHAGEAL PH MONITORING;
D O I
10.1007/BF01307571
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Twenty-four-hour esophageal pH monitoring is regarded as the gold standard investigation for gastroesophageal reflux (GER) (1) and the possibility of an "incorrect" answer, false positive or false negative, is only rarely considered (2). However, when a group of infants in this hospital had such pH studies performed on two consecutive days, considerable differences in the results were found (3). This also had been reported from other centers (4-6). It seems likely that most of the differences were due to true "biological" variability in the amount of GER from day to day, but it remains possible that variation in the accuracy of the equipment in detecting acid reflux was also involved.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 12 条
[1]   ACCURACY AND CHOICE OF PROCEDURES IN 24-HOUR ESOPHAGEAL PH MONITORING WITH MONOCRYSTALLINE ANTIMONY ELECTRODES [J].
ASK, P ;
EDWALL, G ;
JOHANSSON, KE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (06) :602-608
[2]  
DEMEESTER TR, 1976, SURG CLIN N AM, V56, P39
[3]   REPRODUCIBILITY OF 24 HOUR ESOPHAGEAL PH STUDIES IN INFANTS [J].
HAMPTON, FJ ;
MACFADYEN, UM ;
SIMPSON, H .
ARCHIVES OF DISEASE IN CHILDHOOD, 1990, 65 (11) :1249-1254
[4]  
HERRERA JL, 1908, DIGEST DIS SCI, V33, P385
[5]   REPRODUCIBILITY OF AMBULATORY ESOPHAGEAL PH MONITORING [J].
JOHNSSON, F ;
JOELSSON, B .
GUT, 1988, 29 (07) :886-889
[6]   ELECTRODES FOR 24 HOUR PH MONITORING - A COMPARATIVE-STUDY [J].
MCLAUGHLAN, G ;
RAWLINGS, JM ;
LUCAS, ML ;
MCCLOY, RF ;
CREAN, GP ;
MCCOLL, KEL .
GUT, 1987, 28 (08) :935-939
[7]   ASSESSMENT OF ACCURACY OF INTRAESOPHAGEAL PH PROBE IN A DOG-MODEL [J].
MURPHY, DW ;
FAUST, KB ;
CHIANTELLA, VM ;
CASTELL, DO .
DIGESTIVE DISEASES AND SCIENCES, 1989, 34 (07) :1079-1084
[8]   DOES THE INTRAESOPHAGEAL PH PROBE ACCURATELY DETECT ACID REFLUX - SIMULTANEOUS RECORDING WITH 2 PH PROBES IN HUMANS [J].
MURPHY, DW ;
YUAN, Y ;
CASTELL, DO .
DIGESTIVE DISEASES AND SCIENCES, 1989, 34 (05) :649-656
[9]   LIMITATIONS OF 24-HOUR INTRAESOPHAGEAL PH MONITORING IN THE HOSPITAL SETTING [J].
SCHLESINGER, PK ;
DONAHUE, PE ;
SCHMID, B ;
LAYDEN, TJ .
GASTROENTEROLOGY, 1985, 89 (04) :797-804
[10]   REPRODUCIBILITY OF CONTINUOUS 24 HOUR ESOPHAGEAL PH MONITORING IN INFANTS AND CHILDREN [J].
VANDENPLAS, Y ;
HELVEN, R ;
GOYVAERTS, H ;
SACRE, L .
GUT, 1990, 31 (04) :374-377