A RADIOTELEMETRY SYSTEM FOR CHRONIC MEASUREMENT OF BLOOD-PRESSURE AND HEART-RATE IN THE UNRESTRAINED RAT VALIDATION OF THE METHOD

被引:44
作者
GUIOL, C
LEDOUSSAL, C
SURGE, JM
机构
[1] Department of Pharmacology, Bristol-Myers Squibb, Pharmaceutical Research Institute, Lognes
关键词
RADIOTELEMETRY; LONG-TERM MONITORING; CARDIOVASCULAR SYSTEM; UNRESTRAINED RATS;
D O I
10.1016/1056-8719(92)90054-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Chronic measurements of systemic arterial blood pressure and heart rate via a chronically implanted telemetric transmitter in unrestrained rats, was validated in a three-phase study. In the first part, week-to-week variability of systolic, diastolic, and mean arterial pressures, and heart rate was found to be minimal over the course of nine weeks. In the second part, the reproducibility of cardiovascular response to three successive administration of sotalol, an antihypertensive agent, was studied. In the last part, cardiovascular parameters determined by telemetry were compared to those obtained by direct arterial catheterization and showed a good linear correlation between those two methods.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 11 条
  • [1] ARMENTANO R, 1990, MED PROG TECHNOL, V16, P125
  • [2] BROCKWAY BP, 1989, C SHR RELATED STUDIE
  • [3] MULTICHANNEL IMPLANTABLE TELEMETRY SYSTEM FOR FLOW, PRESSURE, AND ECG MEASUREMENTS
    FRYER, TB
    SANDLER, H
    FREUND, W
    MCCUTCHEON, EP
    CARLSON, EL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (02) : 318 - 326
  • [4] GREENE SA, 1991, AM J VET RES, V52, P665
  • [5] IDENTIFICATION AND EVALUATION OF NON-INVASIVE BLOOD-PRESSURE MEASURING TECHNIQUES
    HASSLER, CR
    LUTZ, GA
    LINEBAUGH, R
    CUMMINGS, KD
    [J]. TOXICOLOGY AND APPLIED PHARMACOLOGY, 1979, 47 (02) : 193 - 201
  • [6] MACKAY X, 1970, SENSING TRANSMITTING, P11
  • [7] A NEW MINIATURIZED MULTICHANNEL PERSONAL RADIOTELEMETRY SYSTEM
    MURRAY, RH
    MARKO, A
    KISSEN, AT
    MCGUIRE, DW
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (04) : 588 - &
  • [8] TELEMETRY OF ELECTROPHYSIOLOGIC VARIABLES FROM CONSCIOUS DOGS - SYSTEM-DESIGN, VALIDATION, AND SERIAL STUDIES
    RUBENSON, D
    GRIFFIN, JC
    FORD, A
    CLAUDE, J
    REITZ, B
    KNUTTI, J
    BILLINGHAM, M
    HARRISON, DC
    [J]. AMERICAN HEART JOURNAL, 1984, 107 (01) : 90 - 96
  • [9] SANDLER H, 1972, CIRC RES, V30, pS85
  • [10] TELEMETRY OF BLOOD PRESSURE IN FREE-RANGING ANIMALS VIA AN INTRAVASCULAR GAUGE
    VANCITTE.RL
    FRANKLIN, DL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (05) : 1633 - &