EFFECT OF NEEDLE PUNCTURE ON MORPHINE AND LIDOCAINE FLUX THROUGH THE SPINAL MENINGES OF THE MONKEY IN-VITRO - IMPLICATIONS FOR COMBINED SPINAL EPIDURAL-ANESTHESIA

被引:87
作者
BERNARDS, CM [1 ]
KOPACZ, DJ [1 ]
MICHEL, MZ [1 ]
机构
[1] VIRGINIA MASON MED CTR,SEATTLE,WA 98101
关键词
ANESTHETIC TECHNIQUES; COMBINED SPINAL-EPIDURAL; ANESTHETICS; LOCAL; LIDOCAINE; OPIOID; MORPHINE; COMPLICATIONS; DURAL PUNCTURE; EQUIPMENT; NEEDLES; TUOHY; SPROTTE; WHITACRE;
D O I
10.1097/00000542-199404000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Combined spinal-epidural anesthesia is a technique growing in popularity. However, there have been no attempts to investigate the risk of epidural drug reaching the subarachnoid space in high concentration by passing through the meningeal hole left by the spinal needle. This study begins to address this question by quantitating the nux of morphine and lidocaine through the spinal meninges of the monkey in vitro after puncture with three different-sized needles. Methods: Spinal meningeal tissue from anesthetized monkeys was mounted in a diffusion cell and drug nux was measured through intact tissue and through tissue punctured with a 27-G Whitacre, a 24-G Sprotte, and an 18-G Tuohy needle. Results: The flux of morphine through the meningeal tissue was significantly increased by puncture with each of the study needles. The flux of lidocaine was significantly increased only by puncture with the 24-6 Sprotte and 18-6 Tuohy needles. The nux of morphine through intact tissue was less than the flux of lidocaine through intact tissue. In contrast, the flux of morphine and lidocaine were the same through tissue punctured with the study needles. The magnitude of the drug nux through the needle puncture was a function of the diameter of the study needle. Conclusions: Epidural anesthesia after accidental or intentional puncture of the spinal meninges has occasionally resulted in high spinal blocks and total spinal anesthesia. This study suggests that drug movement through the meningeal hole is responsible for this complication and that the risk may be decreased by using the smallest possible needle to puncture the meninges.
引用
收藏
页码:853 / 858
页数:6
相关论文
共 16 条
[1]   MORPHINE AND ALFENTANIL PERMEABILITY THROUGH THE SPINAL DURA, ARACHNOID, AND PIA MATER OF DOGS AND MONKEYS [J].
BERNARDS, CM ;
HILL, HF .
ANESTHESIOLOGY, 1990, 73 (06) :1214-1219
[2]   PHYSICAL AND CHEMICAL-PROPERTIES OF DRUG MOLECULES GOVERNING THEIR DIFFUSION THROUGH THE SPINAL MENINGES [J].
BERNARDS, CM ;
HILL, HF .
ANESTHESIOLOGY, 1992, 77 (04) :750-756
[3]   POSITION OF PLASTIC TUBING IN CONTINUOUS-BLOCK TECHNIQUES - AN X-RAY STUDY OF 552 PATIENTS [J].
BRIDENBAUGH, LD ;
MOORE, DC ;
BAGDI, P ;
BRIDENBAUGH, PO .
ANESTHESIOLOGY, 1968, 29 (05) :1047-+
[4]  
Bromage PR, 1978, EPIDURAL ANALGESIA, V1st, P160
[5]   EXTRADURAL, SPINAL OR COMBINED BLOCK FOR OBSTETRIC SURGICAL ANESTHESIA [J].
CARRIE, LES .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) :225-233
[6]  
Coombs DW, 1979, REGION ANESTH, V4, P3
[7]   NEEDLE-THROUGH-NEEDLE TECHNIQUE FOR COMBINED SPINAL EXTRADURAL ANESTHESIA IN OBSTETRICS [J].
FAMILTON, MJG ;
MORGAN, BM .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (03) :327-327
[9]   COMBINED SPINAL-EPIDURAL ANESTHESIA USING NEEDLE-THROUGH-NEEDLE TECHNIQUE [J].
JOSHI, GP ;
MCCARROLL, SM .
ANESTHESIOLOGY, 1993, 78 (02) :406-407
[10]   SUBARACHNOID SPREAD OF EPIDURAL LOCAL-ANESTHETIC FOLLOWING DURAL PUNCTURE [J].
LEACH, A ;
SMITH, GB .
ANAESTHESIA, 1988, 43 (08) :671-674