CERTIFIED REFERENCE MATERIALS FOR THE QUALITY-CONTROL OF MEASUREMENTS IN ENVIRONMENTAL MONITORING

被引:39
作者
MAIER, EA [1 ]
机构
[1] UNIV STRASBOURG 1,PHARM,F-67070 STRASBOURG,FRANCE
关键词
D O I
10.1016/0165-9936(91)87011-T
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The monitoring and protection of the environment are based on measurement campaigns which cover long periods of time and large geographical areas. Only accurate analytical results allow valid conclusions to be drawn about a situation and its evolution. The use of certified reference materials (CRMs) permits verification of the accuracy of the measurements. The importance of accuracy and the way CRMs may be used are presented in this review. The production and properties required of a good CRM are discussed. An overview of the types of CRMs in the non-nuclear field, available for the monitoring of the environment, is also given.
引用
收藏
页码:340 / 347
页数:8
相关论文
共 27 条
  • [1] BERMAN SS, 1987, JMG6TMSW7
  • [2] RESULTS OF A COORDINATED RESEARCH-PROGRAM TO IMPROVE THE CERTIFICATION OF IAEA MILK POWDER A-11 AND ANIMAL MUSCLE H-4 FOR 11 DIFFICULT TRACE-ELEMENTS
    BYRNE, AR
    CAMARARICA, C
    CORNELIS, R
    DEGOEIJ, JJM
    IYENGAR, GV
    KIRKBRIGHT, G
    KNAPP, G
    PARR, RM
    STOEPPLER, M
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (07): : 723 - 729
  • [3] Cortes Toro E., 1990, IAEARL128
  • [4] CERTIFICATION OF TRACE-ELEMENT CONTENTS (AS, CD, CO, CU, FE, MN, HG, NA, PB AND ZN) IN A FLY-ASH OBTAINED FROM THE COMBUSTION OF PULVERIZED COAL
    GRIEPINK, B
    COLINET, E
    GUZZI, G
    HAEMERS, L
    MUNTAU, H
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 315 (01): : 20 - 25
  • [5] CERTIFICATION OF THE CONTENTS OF CADMIUM, COPPER, MANGANESE, MERCURY, LEAD AND ZINC IN 2 PLANT MATERIALS OF AQUATIC ORIGIN AND IN OLIVE LEAVES
    GRIEPINK, B
    MUNTAU, H
    COLINET, E
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 315 (03): : 193 - 196
  • [6] CERTIFIED REFERENCE MATERIALS (CRMS) FOR THE QUALITY OF MEASUREMENT
    GRIEPINK, B
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (07): : 812 - 816
  • [7] HARTLEY TH, 1990, COMPUTERIZED QUALITY, P99
  • [8] LEICHNITZ K, 1986, SICHERHEITSINGENIEUR, V7, P24
  • [9] LOKMAN RB, 1980, J ASSOC OFF ANA CHEM, V63, P766
  • [10] ACCURACY IN ANALYSES OF BIOLOGICAL-MATERIALS
    MARCHANDISE, H
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (07): : 613 - 617