A SIMPLE DEVICE FOR KINEMATIC MEASUREMENTS OF HUMAN MOVEMENT

被引:35
作者
BELLI, A [1 ]
REY, S [1 ]
BONNEFOY, R [1 ]
LACOUR, JR [1 ]
机构
[1] UNIV LYON SUD,F-42650 ST JEAN BONNEFOND,FRANCE
关键词
3-DIMENSIONAL KINEMATIC MEASUREMENTS; HUMAN MOVEMENT;
D O I
10.1080/00140139208967805
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple device for three-dimensional recording of human movement was developed. It consisted of four rigid bars linked together by three joints. At each joint an optical transducer, connected to a PC computer via an electronic interface, measured the joint angle, rendering it possible to compute the displacement of one end (measuring end) relative to the other (reference end). This kinematic arm was validated (i) in static conditions; (ii) in dynamic conditions; and (iii) during human jumping. The measured error was 0.4% +/- 0.5% (mean +/- s.d.) on distance measurements in static conditions, 0.1% +/- 1.6% on 0.57 m.s-1 rotation velocity measurements and 3.2% +/- 3.3% on 3.56 m.s-2 rotation acceleration measurements, and 1.6% +/- 20.7% on force measurements during human jumping. These error values are equivalent to or lower than errors linked to tracking systems or to film or video analysis. Therefore, if the movement is not disturbed by the spatial limitation due to the mechanical link with the measuring end, the kinematic arm provides a simple and fast tool to study three-dimensional human movements.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 19 条
[1]   BIOMECHANICAL ANALYSIS OF DROP AND COUNTERMOVEMENT JUMPS [J].
BOBBERT, MF ;
MACKAY, M ;
SCHINKELSHOEK, D ;
HUIJING, PA ;
SCHENAU, GJV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 54 (06) :566-573
[2]   PRE-STRETCH POTENTIATION OF HUMAN SKELETAL-MUSCLE DURING BALLISTIC MOVEMENT [J].
BOSCO, C ;
KOMI, PV ;
ITO, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1981, 111 (02) :135-140
[3]   FORCE PLATFORMS AS ERGOMETERS [J].
CAVAGNA, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (01) :174-179
[4]   MECHANICAL WORK IN RUNNING [J].
CAVAGNA, GA ;
SAIBENE, FP ;
MARGARIA, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (02) :249-&
[5]   MEASUREMENT OF SHORT-TERM POWER OUTPUT - COMPARISON BETWEEN CYCLING AND JUMPING [J].
DAVIES, CTM ;
WEMYSSHOLDEN, J ;
YOUNG, K .
ERGONOMICS, 1984, 27 (03) :285-296
[6]   A BIOMECHANICAL STUDY OF THE TRIPLE JUMP [J].
FUKASHIRO, S ;
IIMOTO, Y ;
KOBAYASHI, H ;
MIYASHITA, M .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1981, 13 (04) :233-237
[7]  
FUKASHIRO S, 1987, INT J SPORTS MED, V8, P15
[8]   A TREADMILL-MOUNTED FORCE PLATFORM [J].
KRAM, R ;
POWELL, AJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (04) :1692-1698
[9]   A QUANTITATIVE COMPARISON OF A POSITION MEASUREMENT SYSTEM AND ACCELEROMETRY [J].
LADIN, Z ;
FLOWERS, WC ;
MESSNER, W .
JOURNAL OF BIOMECHANICS, 1989, 22 (04) :295-&
[10]   FORCE-VELOCITY, POWER-VELOCITY, AND ELASTICITY-VELOCITY RELATIONSHIPS IN WALKING, RUNNING, AND JUMPING [J].
LUHTANEN, P ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 44 (03) :279-289