CT SIMULATOR - A NEW 3-D PLANNING AND SIMULATING SYSTEM FOR RADIOTHERAPY .2. CLINICAL-APPLICATION

被引:38
作者
NAGATA, Y
NISHIDAI, T
ABE, M
TAKAHASHI, M
OKAJIMA, K
YAMAOKA, N
ISHIHARA, H
KUBO, Y
OHTA, H
KAZUSA, C
机构
[1] SHIMADZU CO LTD,DIV MED SYST,KYOTO 604,JAPAN
[2] NEC CORP LTD,DIV MED SYST,TOKYO 183,JAPAN
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 18卷 / 03期
关键词
Clinical application; CT simulator; Radiotherapy treatment planning;
D O I
10.1016/0360-3016(90)90053-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have performed radiotherapy treatment planning (RTP) with a new system called CT simulator in 72 patients. With the system, RTP is performed with the patient lying on the CT couch within a short period of time. All the CT images scanned were immediately transported to the multi-image monitors and to the treatment planning device. Radiotherapy treatment planning could be performed not only at the beam center but also at any CT slice. Using a laser-beam field projector, field outlines were drawn over the patient's skin. In clinical use, the system was useful for cases in which a target lies adjacent to dose limiting organs, cases with a complicated target shape, cases with complicated dose distribution curves, and cases treated with tangential fields. This system enables us to make optimum use of CT information and to make accurate 3-dimensional treatment planning programs. © 1990.
引用
收藏
页码:505 / 513
页数:9
相关论文
共 9 条
[1]   DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE [J].
AUSTINSEYMOUR, MM ;
CHEN, GTY ;
CASTRO, JR ;
SAUNDERS, WM ;
PITLUCK, S ;
WOODRUFF, KH ;
KESSLER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01) :31-35
[2]   THE RESPECTIVE ROLES OF THE SIMULATOR AND COMPUTED-TOMOGRAPHY IN RADIOTHERAPY PLANNING - A REVIEW [J].
DOBBS, HJ ;
PARKER, RP .
CLINICAL RADIOLOGY, 1984, 35 (06) :433-439
[3]   THE IMAGING REVOLUTION AND RADIATION ONCOLOGY - USE OF CT, ULTRASOUND, AND NMR FOR LOCALIZATION, TREATMENT PLANNING AND TREATMENT DELIVERY [J].
GLATSTEIN, E ;
LICHTER, AS ;
FRAASS, BA ;
KELLY, BA ;
VANDEGEIJN, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (02) :299-314
[4]   RADIOTHERAPY PLANNING - DIRECT TUMOR LOCATION ON SIMULATION AND PORT FILMS USING CT .1. PRINCIPLES [J].
HAYNOR, DR ;
BORNING, AW ;
GRIFFIN, BA ;
JACKY, JP ;
KALET, IJ ;
SHUMAN, WP .
RADIOLOGY, 1986, 158 (02) :537-540
[5]  
HOLDAY P, 1979, RADIOLOGY, V133, P477
[6]  
INAMURA K, 1984, 8TH ICCR P, P230
[7]  
INAMURA K, 1984, 8TH P ICCR, P456
[8]  
LING CC, 1983, COMPUTED TOMOGRAPHY
[9]   CT SCANNING FOR RADIATION-THERAPY TREATMENT PLANNING OF HEPATOMA [J].
ROSTOCK, RA ;
FISHMAN, EK ;
ORDER, SE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (07) :1413-1418