THE TETRAD AND HEXAD - MAXIMUM BEAM SEPARATION AS A STARTING POINT FOR NONCOPLANAR 3D TREATMENT PLANNING - PROSTATE-CANCER AS A TEST-CASE

被引:38
作者
SAILER, SL [1 ]
ROSENMAN, JG [1 ]
SYMON, JR [1 ]
CULLIP, TJ [1 ]
CHANEY, EL [1 ]
机构
[1] UNIV N CAROLINA,DEPT COMP SCI,CHAPEL HILL,NC
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 30卷 / 02期
关键词
RADIATION THERAPY TREATMENT PLANNING; RADIATION THERAPY TREATMENT PLAN OPTIMIZATION; PROSTATE CARCINOMA;
D O I
10.1016/0360-3016(94)90026-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. Materials and Methods: A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet-an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58 degrees on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. Results: The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams, The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. Conclusions: Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.
引用
收藏
页码:439 / 446
页数:8
相关论文
共 22 条
[1]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[2]   THE USE OF BEAM EYE VIEW VOLUMETRICS IN THE SELECTION OF NONCOPLANAR RADIATION PORTALS [J].
CHEN, GTY ;
SPELBRING, DR ;
PELIZZARI, CA ;
BALTER, JM ;
MYRIANTHOPOULOS, LC ;
VIJAYAKUMAR, S ;
HALPERN, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (01) :153-163
[3]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122
[4]   STRATEGIES FOR TREATING POSSIBLE TUMOR EXTENSION - SOME THEORETICAL CONSIDERATIONS [J].
GOITEIN, M ;
SCHULTHEISS, TE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (08) :1519-1528
[5]   GAIN IN TARGET DOSE FROM USING COMPUTER-CONTROLLED RADIATION-THERAPY (CCRT) IN THE TREATMENT OF NONSMALL CELL LUNG-CANCER [J].
HA, CS ;
KIJEWSKI, PK ;
LANGER, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (02) :335-339
[6]   OBJECTIVE EVALUATION OF 3-D RADIATION TREATMENT PLANS - A DECISION-ANALYTIC TOOL INCORPORATING TREATMENT PREFERENCES OF RADIATION ONCOLOGISTS [J].
JAIN, NL ;
KAHN, MG ;
DRZYMALA, RE ;
EMAMI, BE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (02) :321-333
[7]  
KALET IJ, 1987, 9TH P INT C US COMP, P553
[8]   AN ALGORITHM FOR MAXIMIZING THE PROBABILITY OF COMPLICATION-FREE TUMOR-CONTROL IN RADIATION-THERAPY [J].
KALLMAN, P ;
LIND, BK ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :871-890
[9]   CALCULATION OF COMPLICATION PROBABILITY FACTORS FOR NON-UNIFORM NORMAL TISSUE IRRADIATION - THE EFFECTIVE VOLUME METHOD [J].
KUTCHER, GJ ;
BURMAN, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06) :1623-1630
[10]   HISTOGRAM REDUCTION METHOD FOR CALCULATING COMPLICATION PROBABILITIES FOR 3-DIMENSIONAL TREATMENT PLANNING EVALUATIONS [J].
KUTCHER, GJ ;
BURMAN, C ;
BREWSTER, L ;
GOITEIN, M ;
MOHAN, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :137-146