EXPERIMENTAL GASTROINTESTINAL HEMORRHAGE - DETECTION WITH CONTRAST-ENHANCED MR-IMAGING AND SCINTIGRAPHY

被引:16
作者
GUPTA, H [1 ]
WEISSLEDER, R [1 ]
BOGDANOV, AA [1 ]
BRADY, TJ [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
关键词
CONTRAST MEDIA; COMPARATIVE STUDIES; GASTROINTESTINAL TRACT; HEMORRHAGE; GASTROINTESTINAL TRACT RADIONUCLIDE STUDIES; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; VASCULAR STUDIES;
D O I
10.1148/radiology.196.1.7784574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To examine the use of O-methoxy poly(ethylene)glycol-O'succinyl-N-epsilon-poly(L-lysyl) gadblinium diethylenetriaminepentaacetic acid (MPEG-PL-Gd-DTPA) as a potential magnetic resonance (MR) angiographic contrast agent for the detection of gastrointestinal (GI) bleeding. MATERIALS AND METHODS: MPEG-PL-Gd-DTPA was used for blood pool enhancement, and MPEG-PL-technetium-99m DTPA was used for planar nuclear imaging studies. GI bleeding was tested in rats by controlled injection of contrast material-doped blood through a jejunostomy catheter. MR imaging was performed at 1.5 T. RESULTS: Ideal flip angle, used with a spoiled gradient-echo pulse sequence, was 40 degrees. The smallest amount of hemorrhage detected at MR imaging was 0.05 mL; at nuclear imaging it was 0.02 mL. With the superior spatial resolution of MR imaging, individual loops of contrast material-filled bowel were identified and bleeding points were pinpointed. CONCLUSION: GI hemorrhage can be easily detected at MR imaging if a long circulating macromolecular contrast agent is used to decrease the T1 of extravasated blood.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 14 条
[1]   SCINTIGRAPHIC DETECTION OF ACUTE GASTROINTESTINAL BLEEDING [J].
ALAVI, A ;
DANN, RW ;
BAUM, S ;
BIERY, DN .
RADIOLOGY, 1977, 124 (03) :753-756
[2]  
BOGDANOV AA, 1994, J NUCL MED, V35, P1880
[3]   A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES [J].
BOGDANOV, AA ;
WEISSLEDER, R ;
FRANK, HW ;
BOGDANOVA, AV ;
NOSSIF, N ;
SCHAFFER, BK ;
TSAI, E ;
PAPISOV, MI ;
BRADY, TJ .
RADIOLOGY, 1993, 187 (03) :701-706
[4]  
DUSOLD R, 1994, AM J GASTROENTEROL, V89, P345
[5]   DETECTION OF PULMONARY EMBOLI BY USING MR-ANGIOGRAPHY WITH MPEG-PL-GDDTPA - AN EXPERIMENTAL-STUDY IN RABBITS [J].
FRANK, H ;
WEISSLEDER, R ;
BOGDANOV, AA ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) :1041-1046
[6]  
FRIEDMAN LS, 1993, GASTROENTEROL CLIN N, V22, P717
[7]  
GUPTA SM, 1991, J NUCL MED, V32, P2249
[8]   LIMITED VALUE OF TC-99M-LABELED RED-CELL SCINTIGRAPHY IN LOCALIZATION OF LOWER GASTROINTESTINAL-BLEEDING [J].
HUNTER, JM ;
PEZIM, ME .
AMERICAN JOURNAL OF SURGERY, 1990, 159 (05) :504-506
[9]  
LEWIS BS, 1994, GASTROENTEROL CLIN N, V23, P67
[10]  
LIEBERMAN D, 1993, GASTROENTEROL CLIN N, V22, P723