A NEW ELECTRONICALLY ENHANCED BIOPSY SYSTEM - VALUE IN IMPROVING NEEDLE-TIP VISIBILITY DURING SONOGRAPHICALLY GUIDED INTERVENTIONAL PROCEDURES

被引:29
作者
PERRELLA, RR
KIMMESMITH, C
TESSLER, FN
RAGAVENDRA, N
GRANT, EG
机构
[1] Dept. Radiological Sciences, UCLA School of Medicine, Los Angeles, CA 90024
关键词
D O I
10.2214/ajr.158.1.1727345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Sonographically guided fine-needle biopsy procedures are hampered by poor visibility of the needle tip. This study was performed to evaluate a new system for placing needles under sonographic guidance. The Biosponder needle (Advanced Technology Laboratories, Bothell, WA) incorporates a specialized stylet with a passive sensor at its tip. When an ultrasound pulse is detected by the sensor, an electrical signal is transmitted to the sonographic unit by a battery-powered electronic module connected to the stylet and to the scanner. This signal is converted into a bright, flashing marker on the screen at the precise location of the needle tip. The Biosponder system, which uses 20- or 22-gauge needles, was compared with a 20-gauge Turner needle (Cook, Bloomington, IN) in 18 patients with masses or fluid collections and two patients requiring nephrostomy tube placement. The tip of the Turner needle could not be localized precisely in any patient. The shaft of the Turner needle was seen clearly in 13 patients, poorly in three, and was not visualized at all in four patients. Excluding four instances of mechanical failure, the Biosponder system allowed precise localization of the needle tip in every patient and was consistently rated as easier to use than the Turner needle. We conclude that the Biosponder needle, with its precise tip localization and ease of use, is a valuable tool for sonographically guided needle placement.
引用
收藏
页码:195 / 198
页数:4
相关论文
共 7 条
[1]   NEEDLE TIP ECHOGENICITY - A STUDY WITH REAL-TIME ULTRASOUND [J].
BONDESTAM, S ;
KREULA, J .
INVESTIGATIVE RADIOLOGY, 1989, 24 (07) :555-560
[2]   CT AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY - CURRENT TECHNIQUES AND NEW INNOVATIONS [J].
CHARBONEAU, JW ;
READING, CC ;
WELCH, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :1-10
[3]   IMPROVED NEEDLE-TIP VISUALIZATION BY COLOR DOPPLER SONOGRAPHY [J].
HAMPER, UM ;
SAVADER, BL ;
SHETH, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (02) :401-402
[4]  
HOLM HH, 1975, RADIOL CLIN N AM, V13, P493
[5]   ULTRASOUND AS A GUIDE IN PERCUTANEOUS PUNCTURE TECHNIQUE [J].
HOLM, HH ;
KRISTENSEN, JK ;
BARLEBO, H ;
NORTHEVED, A ;
RASMUSSEN, SN .
ULTRASONICS, 1972, 10 (02) :83-+
[6]  
KUROHIJI T, 1990, J ULTRAS MED, V9, P243
[7]   LABORATORY ASSESSMENT OF ULTRASONIC NEEDLE AND CATHETER VISUALIZATION [J].
MCGAHAN, JP .
JOURNAL OF ULTRASOUND IN MEDICINE, 1986, 5 (07) :373-377