DETERMINATION OF INSTANTANEOUS AND AVERAGE BLOOD-FLOW RATES FROM DIGITAL ANGIOGRAMS OF VESSEL PHANTOMS USING DISTANCE-DENSITY CURVES

被引:36
作者
HOFFMANN, KR [1 ]
DOI, K [1 ]
FENCIL, LE [1 ]
机构
[1] UNIV MICHIGAN,DEPT MED,ANN ARBOR,MI 48109
关键词
BLOOD FLOW RATES; ANGIOGRAPHY; PULSATILE FLOW;
D O I
10.1097/00004424-199103000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a new method for quantitation of blood flow rates based on determination of the spatial shift of the distribution of contrast material in opacified vessels in digital angiograms that are acquired while the contrast material proceeds through the vessel. The distance that the contrast material travels during the time between image acquisitions is determined by comparison of density-vs.-distance curves, which represent the distribution of contrast material along the length of the vessel in the respective images. The flow rate between image acquisitions is calculated by multiplication of the distance traveled by the frame rate and the vessel cross-sectional area. Therefore, for high-frame-rate acquisitions, "instantaneous" flow rates can be determined. In these vessel-phantom studies, the root-mean-square (RMS) difference between instantaneous flow rates measured with our technique and those measured with an electromagnetic method was 2.9 ml/sec; the RMS difference for average flow rates was 0.8 ml/sec.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 25 条
[1]   DYNAMIC MECHANISMS IN HUMAN CORONARY STENOSIS [J].
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1984, 70 (06) :917-922
[2]  
BUERSCH JH, 1983, DIGITAL IMAGING CARD, P115
[3]  
DOI K, 1983, RADIOLOGY, V146, P91, DOI 10.1148/radiology.146.1.6849074
[4]   ACCURATE ANALYSIS OF BLOOD-VESSEL SIZES AND STENOTIC LESIONS USING STEREOSCOPIC DSA SYSTEM [J].
FENCIL, LE ;
DOI, K ;
HOFFMAN, KR .
INVESTIGATIVE RADIOLOGY, 1988, 23 (01) :33-41
[5]   MEASUREMENT OF ABSOLUTE FLOW-RATE IN VESSELS USING A STEREOSCOPIC DSA SYSTEM [J].
FENCIL, LE ;
DOI, K ;
CHUA, KG ;
HOFFMAN, KR .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :659-671
[6]   PHANTOM TESTING OF PERIPHERAL ARTERY - ABSOLUTE BLOOD-FLOW MEASUREMENT WITH DIGITAL ARTERIOGRAPHY [J].
FORBES, G ;
GRAY, JE ;
FELMLEE, JP .
INVESTIGATIVE RADIOLOGY, 1985, 20 (02) :186-192
[7]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .2. COMPUTERIZED DETERMINATION OF VESSEL SIZES IN DIGITAL SUBTRACTION ANGIOGRAPHY [J].
FUJITA, H ;
DOI, K ;
FENCIL, LE ;
CHUA, KG .
MEDICAL PHYSICS, 1987, 14 (04) :549-556
[8]  
HOFFMANN KR, 1987, P SPIE MED IMAGING, V767, P499
[9]  
KENET RO, 1988, COMPUT CARDIOL, V819, P13
[10]  
KORBULY DE, 1973, INVEST RADIOL, V8, P255