THERMAL TESTING - NORMATIVE DATA AND REPEATABILITY FOR VARIOUS TEST ALGORITHMS

被引:238
作者
YARNITSKY, D
SPRECHER, E
机构
[1] RAMBAM MED CTR,INST CLIN NEUROPHYSIOL,HAIFA,ISRAEL
[2] TECHNION ISRAEL INST TECHNOL,SCH MED,HAIFA,ISRAEL
关键词
THERMAL TESTING; THRESHOLD; LIMITS; LEVELS; STAIRCASE; REPEATABILITY;
D O I
10.1016/0022-510X(94)90239-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Measurement of thresholds for warm and cold sensation was performed on 106 normal subjects, at thenar eminence and foot dorsum. Three test algorithms were used, the reaction-time-inclusive method of limits, and reaction-time-exclusive methods of levels and staircase. Tests were repeated 2 weeks following the first for most of the subjects, and after elimination of 5 outlying subject data points, and determination of no systematic relationship between magnitude and variability of test scores, data from between 72 and 76 subjects were used to derive repeatability coefficients, by ANOVA-based procedures which extend standard repeatability assessment methods. Normative data tables are presented, with measures of repeatability for the various algorithms and modalities. Method of limits tests exhibited inter-session bias, and large repeatability coefficients, compared with methods of levels and staircase, which exhibited no bias and had better (lower) repeatability coefficients. All three methods had similar test durations. We conclude that on the basis of these data, the reaction-time-exclusive methods of levels and staircase have a definite advantage over the method of limits.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 27 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   THERMAL SENSITIVITY TESTER - DEVICE FOR QUANTITATIVE ASSESSMENT OF THERMAL SENSE IN DIABETIC NEUROPATHY [J].
AREZZO, JC ;
SCHAUMBURG, HH ;
LAUDADIO, C .
DIABETES, 1986, 35 (05) :590-592
[3]   THERMAL DISCRIMINATION THRESHOLDS IN NORMAL SUBJECTS AND IN PATIENTS WITH DIABETIC NEUROPATHY [J].
BERTELSMANN, FW ;
HEIMANS, JJ ;
WEBER, EJM ;
VANDERVEEN, EA ;
SCHOUTEN, JA .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1985, 48 (07) :686-690
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   THERMAL THRESHOLD TESTING FOR THE ASSESSMENT OF SMALL FIBER DYSFUNCTION - NORMAL VALUES AND REPRODUCIBILITY [J].
BRAVENBOER, B ;
VANDAM, PS ;
HOP, J ;
VANDERSTEENHOVEN, J ;
ERKELENS, DW .
DIABETIC MEDICINE, 1992, 9 (06) :546-549
[6]   METHODS OF MEASUREMENT OF THERMAL THRESHOLDS [J].
CLAUS, D ;
HILZ, MJ ;
HUMMER, I ;
NEUNDORFER, B .
ACTA NEUROLOGICA SCANDINAVICA, 1987, 76 (04) :288-296
[7]   THERMAL DISCRIMINATION THRESHOLDS - A COMPARISON OF DIFFERENT METHODS [J].
CLAUS, D ;
HILZ, MJ ;
NEUNDORFER, B .
ACTA NEUROLOGICA SCANDINAVICA, 1990, 81 (06) :533-540
[8]   THE RELATIONSHIP OF COLD AND WARMTH CUTANEOUS SENSATION TO AGE AND GENDER [J].
DOELAND, HJ ;
NAUTA, JJP ;
VANZANDBERGEN, JB ;
VANDEREERDEN, HAM ;
VANDIEMEN, NGJ ;
BERTELSMANN, FW ;
HEIMANS, JJ .
MUSCLE & NERVE, 1989, 12 (09) :712-715
[9]   INTRODUCTION OF AUTOMATED SYSTEMS TO EVALUATE TOUCH-PRESSURE, VIBRATION, AND THERMAL CUTANEOUS SENSATION IN MAN [J].
DYCK, PJ ;
ZIMMERMAN, IR ;
OBRIEN, PC ;
NESS, A ;
CASKEY, PE ;
KARNES, J ;
BUSHEK, W .
ANNALS OF NEUROLOGY, 1978, 4 (06) :502-510
[10]   COMPARISON OF ALGORITHMS OF TESTING FOR USE IN AUTOMATED EVALUATION OF SENSATION [J].
DYCK, PJ ;
KARNES, JL ;
GILLEN, DA ;
OBRIEN, PC ;
ZIMMERMAN, IR ;
JOHNSON, DM .
NEUROLOGY, 1990, 40 (10) :1607-1613