COMPARISON OF IOHEXOL-240 VERSUS IOHEXOL-300 IN ABDOMINAL CT

被引:15
作者
SINGER, AA
TAGLIABUE, JR
PAUSHTER, DM
BORKOWSKI, GP
EINSTEIN, DM
机构
[1] Department of Radiology, Cleveland Clinic Foundation, Cleveland, 44195, OH, One Clinic Center Drive
来源
GASTROINTESTINAL RADIOLOGY | 1992年 / 17卷 / 02期
关键词
ABDOMEN; CT; CONTRAST MEDIA; NONIONIC; LIVER;
D O I
10.1007/BF01888525
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Forty patients without evidence of liver, kidney, or significant cardiac disease were prospectively divided into two groups of 20, receiving either iohexol-240 or iohexol-300. A contrast load of 150 ml was administered in conjunction with a rapid scanning technique at a preselected, fixed level to include liver, renal cortex, and aorta. Peak enhancement was calculated as change in Hounsfield units (HU) over baseline for each area of interest. Mean peak enhancement and standard deviation were calculated for each organ, and the difference between the means for the two contrast agents was compared using the Student's t test. Differences were not statistically significant with all p values greater than 0.05. Our results suggest iohexol-240 is preferred to iohexol-300 for body computed tomography (CT) due to its lower cost and iodine load without statistically significant change in diagnostic quality of the examination.
引用
收藏
页码:122 / 124
页数:3
相关论文
共 16 条
[1]   ANGIOGRAPHIC CONTRAST AGENTS - CONVENTIONAL AND NEW MEDIA COMPARED [J].
BETTMANN, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (04) :787-794
[2]   LOW-OSMOLALITY CONTRAST-MEDIA - GOOD-NEWS OR BAD [J].
EVENS, RG .
RADIOLOGY, 1988, 169 (01) :277-278
[3]  
HALVORSEN RA, 1984, INVEST RADIOL S, pS239
[4]   THE INTRODUCTION OF LOW-OSMOLAR CONTRAST AGENTS IN RADIOLOGY - MEDICAL, ECONOMIC, LEGAL, AND PUBLIC-POLICY ISSUES [J].
JACOBSON, PD ;
ROSENQUIST, CJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 260 (11) :1586-1592
[5]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[6]   CONTRAST-ENHANCED CT OF THE LIVER AND SPLEEN - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS [J].
NELSON, RC ;
CHEZMAR, JL ;
PETERSON, JE ;
BERNARDINO, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :973-976
[7]  
PALMER F J, 1988, Australasian Radiology, V32, P426, DOI 10.1111/j.1440-1673.1988.tb02770.x
[8]   CT EVALUATION OF SUSPECTED HEPATIC METASTASES - COMPARISON OF TECHNIQUES FOR IV CONTRAST ENHANCEMENT [J].
PAUSHTER, DM ;
ZEMAN, RK ;
SCHEIBLER, ML ;
CHOYKE, PL ;
JAFFE, MH ;
CLARK, LR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (02) :267-271
[9]  
PAUSHTER DM, 1990, CT MRI LIVER BILIARY, P21
[10]  
PENRY JB, 1982, CLIN RADIOL, V23, P362