MOIST BACTERIAL STRIKE-THROUGH OF SURGICAL MATERIALS - CONFIRMATORY TESTS

被引:21
作者
LAUFMAN, H [1 ]
SIEGAL, JD [1 ]
EDBERG, SC [1 ]
机构
[1] MONTEFIORE HOSP & MED CTR,DEPT PATHOL,DIV MICROBIOL,BRONX,NY 10467
关键词
D O I
10.1097/00000658-197901000-00014
中图分类号
R61 [外科手术学];
学科分类号
摘要
New tests consisting of modifications of the inverted Mason jar test confirm our previously reported studies which showed that woven and nonwoven surgical materials vary greatly in their ability to serve as barriers against moist bacterial strikethrough. Among the woven materials, only tightly woven Pima cloth or materials treated with Quarpel waterproofing process or with polythene layer lamination was invariably resistant. However, tight-woven Pima cloth, which had been treated with Quarpel became permeable after 100 washing-sterilizing cycles. Of the nonwoven materials, single-layer nonwoven materials tended to be unevenly permeable to moist bacterial strike-through. Only the front and sleeves of nonwoven gowns reinforced with polyethelene layer were invariably resistant to moist contamination.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 8 条
[1]  
BECK WC, 1969, GUTHRIE CLIN B, V39, P52
[2]   STRIKE-THROUGH OF MOIST CONTAMINATION BY WOVEN AND NONWOVEN SURGICAL MATERIALS [J].
LAUFMAN, H ;
EUDY, WW ;
VANDERNOOT, AM ;
LIU, D ;
HARRIS, CA .
ANNALS OF SURGERY, 1975, 181 (06) :857-862
[3]  
LAUFMAN H, 1977, SURG GYNECOL OBSTET, V145, P242
[4]  
LIBMAN GN, 1973, JAN TECHN S NONW PRO
[5]  
MOYLAN JA, 1973, SURG GYNECOL OBSTET, V141, P731
[6]  
1971, AATCC TECHNICAL MANU
[7]  
1975, AORN J, V21, P4
[8]  
1970, FLUID REPELLENCY DIS