POROUS ENDOCARDIAL ELECTRODE

被引:46
作者
AMUNDSON, DC
MCARTHUR, W
MOSHARRAFA, M
机构
[1] Cardiac Pacemakers, Inc., St. Paul, Minnesota
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1979年 / 2卷 / 01期
关键词
dislodgement; endocardial electrode; threshold;
D O I
10.1111/j.1540-8159.1979.tb05174.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AMUNDSON, D.C., McARTHUR, W., AND MOSHARRAFA, M.: The porous endocardial electrode. The permanent endocardial electrode has exhibited the problems of dislodgement, excessive threshold rises and Joss of sensing. These failure modes are addressed with a new electrode incorporating a porous body of Pt‐Ir fibers with a fiber diameter of 20 μm and an overall density of 10%. Porous electrodes have the advantages of utilizing the electrode interior both for tissue ingrowth to improve anchoring and for electrolyte penetration which improves fl wave amplitude and reduces polarization losses. A series of 20 porous electrodes was compared with 17 solid electrodes of similar dimension. Electrodes were implanted in dogs in the apex of the right ventricle, and were subsequently followed up to 210 days. Comparison of the electrode data revealed that the porous electrodes had a 40% reduction in chronic voltage thresholds and had an overall dislodgement rote of 10%, compared to 53% for (he solid electrodes. Histological examination revealed tissue ingrowths throughout the electrode interior and a fibrotic capsule about half (he thickness of the solid electrodes. R wave stability was enhanced with the porous electrode due to improved anchoring, reduction in slew rate changes and less R wave attenuation. Assuming results are translatable to humans, the porous elctrode will provide a greater pacing safety margin when used with a standard demand pacemaker, or improved longevity with the same safety margin as solid electrodes if used with a programmable pacemaker. The incidence of dislodgement and sensing failure will also be diminished with the porous electrode. (PACE, Volume 2, January‐February, 1.979) Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:40 / 50
页数:11
相关论文
共 16 条
[1]  
AMUNDSON DC, 78TH ACEMB, P83
[2]  
BRAUNWALD NS, 1969, PROSTHETIC HEART VAL, P228
[3]   FOREIGN-BODY REACTION - CHRONIC INFLAMMATORY RESPONSE [J].
COLEMAN, DL ;
KING, RN ;
ANDRADE, JD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1974, 8 (05) :199-211
[4]   AN INTRACARDIAC PACEMAKER FOR STOKES-ADAMS SEIZURES [J].
FURMAN, S ;
SCHWEDEL, JB .
NEW ENGLAND JOURNAL OF MEDICINE, 1959, 261 (19) :943-948
[5]   CLINICAL THRESHOLDS OF ENDOCARDIAL CARDIAC STIMULATION - LONG-TERM STUDY [J].
FURMAN, S ;
HURZELER, P ;
PARKER, B .
JOURNAL OF SURGICAL RESEARCH, 1975, 19 (03) :149-155
[6]   SINTERED FIBER METAL COMPOSITES AS A BASIS FOR ATTACHMENT OF IMPLANTS TO BONE [J].
GALANTE, J ;
ROSTOKER, W ;
LUECK, R ;
RAY, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (01) :101-&
[7]  
HARPER R, 1977, CARDIAC PACING, P548
[8]  
HUGHES HC, 1976, CIRCULATION, V54, P127
[9]   TISSUE REACTION TO 3 CERAMICS OF POROUS AND NON-POROUS STRUCTURES [J].
HULBERT, SF ;
MORRISON, SJ ;
KLAWITTER, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1972, 6 (05) :347-+
[10]  
HULBERT SF, 1969, RES DENT MED MAT, P19