VASCULAR REACTIVITY AFTER BALLOON ANGIOPLASTY IN AN ATHEROSCLEROTIC RABBIT

被引:21
作者
LAVEAU, PJ
SAREMBOCK, IJ
SIGAL, SL
YANG, TL
EZEKOWITZ, MD
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED CARDIOL,333 CEDAR ST,NEW HAVEN,CT 06510
[2] YALE UNIV,SCH MED,DEPT MED,NEW HAVEN,CT 06510
关键词
angioplasty; vasomotor reactivity;
D O I
10.1161/01.CIR.82.5.1790
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Alterations in vessel wall reactivity (VR) at or adjacent to the dilation site after balloon angioplasty (BA) may vary according to the inflation protocol and the time after angioplasty and may influence outcome. In 64 atherosclerotic rabbit femoral arteries, we evaluated VR after BA with intravenous ergonovine (ERGO) (40 μg/min for 5 minutes) and intra-arterial nitroglycerin (NTG) (2,500 μg single bolus) 24-72 hours and 28 days after BA. Comparisons were made with atherosclerotic, nonangioplastied, age-matched controls. BA was standardized to three 1-minute inflations, each 1 minute apart. For each balloon size, 2.5- (appropriate size) or 3.0-mm (oversized) vessels were allocated to either 5 or 10 atm inflation pressure. For the analysis, four groups were compared: Group 1, 3.0/0.5; group 2, 3.0/10; group 3, 2.5/5, and group 4, 2.5 mm/10 atm. Angiographic diameters were measured at, proximal, and distal to the lesion at baseline, 10 minutes after ERGO, and 5 minutes after NTG. Angiograms were measured with electronic calipers by two blinded observers. All segments of control vessels vasoconstricted to ERGO and vasodilated to NTG (p < 0.05 versus baseline), indicating a normal response. At 24-72 hours after dilatation, the angioplasty sites for all inflation pressure/balloon size combinations were not responsive to either ERGO or NTG. All segments distal to the dilatation sites vasoconstricted to ERGO and dilated to NTG (p < 0.05 versus baseline), indicating a normal response. Proximal segments of vessels dilated with a 2.5-mm balloon (appropriate size) responded positively to both stimuli (p < 0.05). Those vessels dilated with a large balloon (3.0 mm) were nonreactive in the segment proximal to the angioplasty site. Twenty-eight days later angioplasty sites dilated with a 2.5-mm balloon (appropriately sized) regained reactivity; however, segments dilated with a large balloon (3.0 mm) remained unresponsive. All proximal segments, including those from vessels dilated with a large balloon, reacted positively. All distal segments reacted appropriately. Restenosis rates were not different between the over- and appropriately sized balloon groups. These data demonstrate that immediately after angioplasty, vessels lose reactivity at the dilatation site. Those vessels dilated with the smaller-size balloon (2.5 mm) regained reactivity. For large balloons, reactivity is not regained at 28 days. For segments proximal to the site of dilatation, transient loss of reactivity is seen only when a large balloon is used. Thus, acute closure originating at the site of dilatation is not a result of spasm. In addition, no connection was found between restenosis rates and the ability of the dilatation site to react to ERGO and NTG. Finally, the vessel proximal, and especially distal, to the site of angioplasty remains highly reactive, and spasm originating at those sites may contribute to acute closure.
引用
收藏
页码:1790 / 1801
页数:12
相关论文
共 37 条
  • [1] COMPARATIVE RESULTS OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN PATIENTS WITH DYNAMIC VERSUS FIXED CORONARY STENOSIS
    BERTRAND, ME
    LABLANCHE, JM
    THIEULEUX, FA
    FOURRIER, JL
    TRAISNEL, G
    ASSEMAN, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (03) : 504 - 508
  • [2] RELATION TO RESTENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY TO VASOMOTION OF THE DILATED CORONARY ARTERIAL SEGMENT
    BERTRAND, ME
    LABLANCHE, JM
    FOURRIER, JL
    GOMMEAUX, A
    RUEL, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (05) : 277 - 281
  • [3] MORPHOLOGY AFTER TRANS-LUMINAL ANGIOPLASTY IN HUMAN-BEINGS
    BLOCK, PC
    MYLER, RK
    STERTZER, S
    FALLON, JT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (07) : 382 - 385
  • [4] THE PATHOLOGIC BASIS OF ANGIOPLASTY
    CASTANEDAZUNIGA, WR
    SIBLEY, R
    AMPLATZ, K
    [J]. ANGIOLOGY, 1984, 35 (04) : 195 - 205
  • [5] THE MECHANISM OF BALLOON ANGIOPLASTY
    CASTANEDAZUNIGA, WR
    FORMANEK, A
    TADAVARTHY, M
    VLODAVER, Z
    EDWARDS, JE
    ZOLLIKOFER, C
    AMPLATZ, K
    [J]. RADIOLOGY, 1980, 135 (03) : 565 - 571
  • [6] PARALYSIS OF ARTERIES BY INTRALUMINAL BALLOON DILATATION - AN EXPERIMENTAL-STUDY
    CASTANEDAZUNIGA, WR
    LAERUM, F
    RYSAVY, J
    RUSNAK, B
    AMPLATZ, K
    [J]. RADIOLOGY, 1982, 144 (01) : 75 - 76
  • [7] EFFECTS OF ERGONOVINE MALEATE ON CORONARY ARTERIAL SIZE
    CIPRIANO, PR
    GUTHANER, DF
    ORLICK, AE
    RICCI, DR
    WEXLER, L
    SILVERMAN, JF
    [J]. CIRCULATION, 1979, 59 (01) : 82 - 89
  • [8] IMMEDIATE AND LONG-TERM EFFECTS OF ANGIOPLASTY-BALLOON DILATION ON NORMAL RABBIT ILIAC ARTERY
    CONSIGNY, PM
    TULENKO, TN
    NICOSIA, RF
    [J]. ARTERIOSCLEROSIS, 1986, 6 (03): : 265 - 276
  • [9] ACUTE CORONARY EVENTS ASSOCIATED WITH PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    COWLEY, MJ
    DORROS, G
    KELSEY, SF
    VANRADEN, M
    DETRE, KM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) : C12 - C16
  • [10] FAILURE OF EXPERIMENTAL ATHEROSCLEROSIS TO SENSITIZE CORONARY-ARTERIES TO SPASM IN HYPERCHOLESTEROLEMIC RABBITS
    CREA, F
    VONARNIM, T
    ALLWORK, SP
    JADHAV, A
    THOMPSON, GR
    MASERI, A
    [J]. AMERICAN HEART JOURNAL, 1985, 109 (03) : 491 - 497