MEASUREMENTS OF CARDIAC STROKE VOLUME IN VARIOUS BODY POSITIONS IN PREGNANCY AND DURING CESAREAN-SECTION - COMPARISON BETWEEN THERMODILUTION AND IMPEDANCE CARDIOGRAPHY

被引:70
作者
SECHER, NJ
ARNSBO, P
ANDERSEN, LH
THOMSEN, A
机构
[1] ODENSE UNIV HOSP, DEPT CLIN PHYSIOL, DK-5000 ODENSE, DENMARK
[2] ODENSE UNIV HOSP, DEPT GYNECOL & OBSTET, DK-5000 ODENSE, DENMARK
关键词
Anaesthesia; Body tilt; Caesarean section; Cardiac output; Impedance cardiograph; Pregnancy; Thermodilution technique; Vena cava inferior syndrome;
D O I
10.3109/00365517909108835
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
A total of 220 simultaneous pairs of measurements of cardiac stroke volume were made in twelve women before and during Caesarean section in order to compare impedance cardiography with the thermodilution method. A significantly higher coefficient of correlation was found before (r = 0.77) than during anaesthesia (r = 0.55). Further, there was a significant difference in the slope of the regression lines: before anaesthesia the slope was 1.07 and during anaesthesia with thiopentone, nitrous oxide, oxygen and suxamethonium it was 0.45. Significant changes in the intercept on the F-axis were found before (-13.9 ml) and during anaesthesia (33.4 ml). When the uterus was displaced upwards and to the left from the 15d̀ tilt position the stroke volume and the cardiac output were increased when measured by both methods to nearly the same values as in the left lateral position. It is concluded that the impedance method is reliable for measuring cardiac stroke volume in late pregnancy under physiological conditions in the conscious patient, but that it cannot replace the thermodilution method in pharmacological studies. © 1979 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:569 / 576
页数:8
相关论文
共 22 条
[1]  
BACHE RJ, 1969, AM J MED SCI, V258, P100
[2]  
BAKER L E, 1971, Cardiovascular Research Center Bulletin (Houston), V9, P135
[3]   IMPEDANCE CARDIOGRAPHY, A METHOD TO EVALUATE QUANTITATIVELY CARDIAC-OUTPUT - COMPARISON WITH FICK PRINCIPLE [J].
BETZ, R ;
BASTANIER, CK ;
MOCELLIN, R .
BASIC RESEARCH IN CARDIOLOGY, 1977, 72 (01) :46-56
[4]   MEASUREMENT OF CARDIAC OUTPUT BY THERMAL DILUTION IN MAN [J].
BRANTHWAITE, MA ;
BRADLEY, RD .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (03) :434-+
[5]  
Demange J, 1972, Ann Med Interne (Paris), V123, P1019
[6]   MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE [J].
DENNISTON, JC ;
MAHER, JT ;
REEVES, JT ;
CRUZ, JC ;
CYMERMAN, A ;
GROVER, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) :91-95
[7]   MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY IN PATIENTS WITH MYOCARDIAL-INFARCTION - COMPARATIVE EVALUATION OF IMPEDANCE AND DYE DILUTION METHODS [J].
GABRIEL, S ;
ATTERHOG, JH ;
ORO, L ;
EKELUND, LG .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :29-34
[8]   SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION [J].
GANZ, W ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) :241-+
[9]   SPECIFIC RESISTANCE OF BLOOD AT BODY-TEMPERATURE [J].
GEDDES, LA ;
SADLER, C .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (03) :336-339
[10]  
HARLEY A, 1968, AEROSPACE MED, V39, P248