EFFECT OF ACCESSORY PATHWAY LOCATION ON THE EFFICIENCY OF HEATING DURING RADIOFREQUENCY CATHETER ABLATION

被引:17
作者
STRICKBERGER, SA
HUMMEL, J
GALLAGHER, M
HASSE, C
MAN, KC
WILLIAMSON, B
VORPERIAN, VR
KALBFLEISCH, SJ
MORADY, F
LANGBERG, JJ
机构
[1] Department of Internal Medicine, Division of Cardiology, The University of Michigan Medical Center Ann Arbor, MI
关键词
D O I
10.1016/0002-8703(95)90042-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During radiofrequency catheter ablation of accessory pathways there is a poor correlation between applied power and temperature at target sites for catheter ablation. This study was designed to examine the relation between power and temperature during radiofrequency catheter ablation in patients with accessory pathways and to identify the factors that affect the efficiency of heating, defined as the ratio of applied power and temperature. Twenty-nine patients underwent radiofrequency catheter ablation of an accessory pathway. Among 257 energy applications, 108 were applied for ablation of a right-sided accessory pathway, 105 for a left-sided accessory pathway, and 44 for a posteroseptal accessory pathway. During each application of radiofrequency energy, temperature was continually monitored by use of an ablation catheter with a thermistor embedded in the tip of the distal electrode. During some applications of energy, fluctuations in temperature were observed. The average power, impedance, temperature, and efficiency of heating for all applications of radiofrequency energy was 37 +/- 11 W, 100 +/- 9 ohms, 53 +/- 9 degrees C, and 1.7 +/- 0.8 degrees C/W (range 0.9 degrees to 6.6 degrees C/W), respectively. The efficiency of heating varied by location (p < 0.0001), with the greatest efficiency of heating for posteroseptal energy applications (2.3 +/- 1.2 degrees C/W, which were significantly greater than for left-sided (1.8 +/- 0.8 degrees C/W; p < 0.01) or right-sided (1.2 +/- 0.4 degrees C/W; p < 0.0001) applications. Phasic fluctuation in temperature was observed during 127 (49%) energy applications, and the efficiency of heating was 1.5 +/- 0.7 degrees C/W. For the 130 applications with a stable temperature curve, the efficiency was 1.8 +/- 0.9 degrees C/W (p < 0.02). The mean impedance during energy applications correlated weakly with efficiency (r = 0.2, p = 0.0012). In conclusion, the efficiency of heating varies according to the location of the application of radiofrequency energy. Inadequate contact, as manifested by fluctuating temperature during ablation, results in less efficient heating.
引用
收藏
页码:54 / 58
页数:5
相关论文
共 18 条
  • [1] THE EFFECT OF ELECTRODE DESIGN ON THE EFFICIENCY OF DELIVERY OF RADIOFREQUENCY ENERGY TO CARDIAC TISSUE INVITRO
    BLOUIN, LT
    MARCUS, FI
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01): : 136 - 143
  • [2] DETERMINANTS OF IMPEDANCE DURING RADIOFREQUENCY CATHETER ABLATION IN HUMANS
    BORGANELLI, M
    ELATASSI, R
    LEON, A
    KALBFLEISCH, SJ
    CALKINS, H
    MORADY, F
    LANGBERG, JJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) : 1095 - 1097
  • [3] DIAGNOSIS AND CURE OF THE WOLFF-PARKINSON-WHITE SYNDROME OR PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIAS DURING A SINGLE ELECTROPHYSIOLOGIC TEST
    CALKINS, H
    SOUSA, J
    ELATASSI, R
    ROSENHECK, S
    DEBUITLEIR, M
    KOU, WH
    KADISH, AH
    LANGBERG, JJ
    MORADY, F
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (23) : 1612 - 1618
  • [4] CALKINS H, 1992, CIRCULATION, V85, P656
  • [5] FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
  • [6] HAINES D E, 1991, Journal of Cardiovascular Electrophysiology, V2, P509, DOI 10.1111/j.1540-8167.1991.tb01353.x
  • [7] TISSUE HEATING DURING RADIOFREQUENCY CATHETER ABLATION - A THERMODYNAMIC MODEL AND OBSERVATIONS IN ISOLATED PERFUSED AND SUPERFUSED CANINE RIGHT VENTRICULAR FREE WALL
    HAINES, DE
    WATSON, DD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (06): : 962 - 976
  • [8] COAGULATION OF VENTRICULAR MYOCARDIUM USING RADIOFREQUENCY ALTERNATING-CURRENT - BIO-PHYSICAL ASPECTS AND EXPERIMENTAL FINDINGS
    HAVERKAMP, W
    HINDRICKS, G
    GULKER, H
    RISSEL, U
    PFENNINGS, W
    BORGGREFE, M
    BREITHARDT, G
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01): : 187 - 195
  • [9] RADIOFREQUENCY COAGULATION OF VENTRICULAR MYOCARDIUM - IMPROVED PREDICTION OF LESION SIZE BY MONITORING CATHETER TIP TEMPERATURE
    HINDRICKS, G
    HAVERKAMP, W
    GULKER, H
    RISSEL, U
    BUDDE, T
    RICHTER, KD
    BORGGREFE, M
    BREITHARDT, G
    [J]. EUROPEAN HEART JOURNAL, 1989, 10 (11) : 972 - 984
  • [10] HOFFMANN E, 1985, CIRCULATION S2, V80, P43