A PFG NMR EXPERIMENT FOR ACCURATE DIFFUSION AND FLOW STUDIES IN THE PRESENCE OF EDDY CURRENTS

被引:536
作者
GIBBS, SJ [1 ]
JOHNSON, CS [1 ]
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
来源
JOURNAL OF MAGNETIC RESONANCE | 1991年 / 93卷 / 02期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1016/0022-2364(91)90014-K
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A pulsed-field-gradient NMR experiment that permits accurate measurements of diffusion and flow rates in the presence of eddy currents is presented. The experiment employs short transverse evolution times and is thus especially useful for the study of systems exhibiting fast transverse relaxation or homonuclear scalar coupling. The insensitivity of the experiment to the presence of eddy currents is demonstrated with experiments on 5% polyacrylamide gels. © 1991.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 19 条
[1]   PGSE MASSEY, A SEQUENCE FOR OVERCOMING PHASE INSTABILITY IN VERY-HIGH-GRADIENT SPIN-ECHO NMR [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03) :493-500
[2]   SELF-DIFFUSION MEASUREMENTS USING A RADIOFREQUENCY FIELD GRADIENT [J].
CANET, D ;
DITER, B ;
BELMAJDOUB, A ;
BRONDEAU, J ;
BOUBEL, JC ;
ELBAYED, K .
JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01) :1-12
[3]   NMR DIFFUSION MEASUREMENTS USING REFOCUSED 3-PULSE STIMULATED ECHOES [J].
GRIFFITHS, L ;
HORTON, R ;
COSGROVE, T .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (02) :254-263
[4]   CRITICAL FACTORS IN DESIGN OF SENSITIVE HIGH-RESOLUTION NUCLEAR MAGNETIC-RESONANCE SPECTROMETERS [J].
HOULT, DI ;
RICHARDS, RE .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1975, 344 (1638) :311-340
[5]   NMR PULSED-GRADIENT DIFFUSION MEASUREMENTS .1. SPIN-ECHO STABILITY AND GRADIENT CALIBRATION [J].
HROVAT, MI ;
WADE, CG .
JOURNAL OF MAGNETIC RESONANCE, 1981, 44 (01) :62-75
[6]   NMR PULSED GRADIENT DIFFUSION MEASUREMENTS .2. RESIDUAL GRADIENTS AND LINESHAPE DISTORTIONS [J].
HROVAT, MI ;
WADE, CG .
JOURNAL OF MAGNETIC RESONANCE, 1981, 45 (01) :67-80
[7]   CORRECTION OF DISTORTIONS DUE TO THE PULSED MAGNETIC-FIELD GRADIENT-INDUCED SHIFT IN B0 FIELD BY POSTPROCESSING [J].
JEHENSON, P ;
SYROTA, A .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (02) :253-256
[8]  
JOHNSON CS, 1989, ADV MAGN RESON, V13, P133
[9]  
Karger J., 1988, ADV MAGN OPT RESON, V12, P1
[10]   EDDY-CURRENT COMPENSATION BY DIRECT FIELD DETECTION AND DIGITAL GRADIENT MODIFICATION [J].
MAJORS, PD ;
BLACKLEY, JL ;
ALTOBELLI, SA ;
CAPRIHAN, A ;
FUKUSHIMA, E .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (03) :548-553