SPECTRAL DEPENDENCE OF TEMPORAL POINT SPREAD FUNCTIONS IN HUMAN TISSUES

被引:176
作者
ESSENPREIS, M
ELWELL, CE
COPE, M
VANDERZEE, P
ARRIDGE, SR
DELPY, DT
机构
[1] UNIV HERTFORDSHIRE, DIV PHYS SCI, HARTFIELD AL10 9AB, HERTS, ENGLAND
[2] UCL, DEPT COMP SCI, LONDON WC1, ENGLAND
来源
APPLIED OPTICS | 1993年 / 32卷 / 04期
关键词
NEAR INFRARED; TIME RESOLVED; SPECTROSCOPY; TISSUE; DIFFERENTIAL PATH LENGTH;
D O I
10.1364/AO.32.000418
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have determined the spectral dependence of the temporal point spread functions of human tissues experimentally between 740 and 840 nm in transmittance measurements on the adult head, forearm, and calf (in vivo) and the infant head (post mortem) by using picosecond laser pulses and a streak camera detector. Two parameters are extracted from the temporal point spread function; the differential path-length factor (DPF), calculated from the mean time, and the slope of the logarithmic intensity decay. In all tissues the DPF and the logarithmic slope show a reciprocal relationship and exhibit characteristics of the absorption spectra of hemoglobin. The DPF falls with increasing wavelength, the variation being typically 12%, while the logarithmic slope increases with wavelength. A quantitative analysis of the logarithmic slope spectrum significantly underestimated expected tissue chromophore concentrations. The absolute magnitudes of the DPF showed considerable intersubject variation, but the variation with wavelength was consistent and thus may be used in the correction of tissue attenuation spectra.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 35 条
  • [1] REFRACTIVE-INDEX OF SOME MAMMALIAN-TISSUES USING A FIBER OPTIC CLADDING METHOD
    BOLIN, FP
    PREUSS, LE
    TAYLOR, RC
    FERENCE, RJ
    [J]. APPLIED OPTICS, 1989, 28 (12): : 2297 - 2303
  • [2] Brante G., 1949, ACTA PHYSIOL SCA S63, V18, P1
  • [3] CYTOCHROME-OXIDASE CONTENT OF RAT-BRAIN DURING DEVELOPMENT
    BROWN, GC
    CROMPTON, M
    WRAY, S
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1057 (02) : 273 - 275
  • [4] BRUNORI M, 1981, METAL IONS BIOL SYST
  • [5] COMPARISON OF TIME-RESOLVED AND TIME-UNRESOLVED MEASUREMENTS OF DEOXYHEMOGLOBIN IN BRAIN
    CHANCE, B
    LEIGH, JS
    MIYAKE, H
    SMITH, DS
    NIOKA, S
    GREENFELD, R
    FINANDER, M
    KAUFMANN, K
    LEVY, W
    YOUNG, M
    COHEN, P
    YOSHIOKA, H
    BORETSKY, R
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (14) : 4971 - 4975
  • [6] TIME-RESOLVED SPECTROSCOPY OF HEMOGLOBIN AND MYOGLOBIN IN RESTING AND ISCHEMIC MUSCLE
    CHANCE, B
    NIOKA, S
    KENT, J
    MCCULLY, K
    FOUNTAIN, M
    GREENFELD, R
    HOLTOM, G
    [J]. ANALYTICAL BIOCHEMISTRY, 1988, 174 (02) : 698 - 707
  • [7] Cope M, 1989, Adv Exp Med Biol, V248, P33
  • [8] COPE M, 1991, P SOC PHOTO-OPT INS, V1431, P251, DOI 10.1117/12.44196
  • [9] SYSTEM FOR LONG-TERM MEASUREMENT OF CEREBRAL BLOOD AND TISSUE OXYGENATION ON NEWBORN-INFANTS BY NEAR-INFRARED TRANS-ILLUMINATION
    COPE, M
    DELPY, DT
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (03) : 289 - 294
  • [10] Cope M, 1991, DEV NEAR INFRARED SP